![background image](http://html.mh-extra.com/html/omron/zs-l/zs-l_user-manual_1633386040.webp)
2-12
S
ect
io
n
2
IN
STALLATION &
CONNECTI
O
N
ZS-L
User’s Manual
Section 2
Sensor Head
Installing the Sensor Head
This section describes how to install Sensor Heads.
■
Adjusting the installation position
The position of Sensor Head must be adjusted to match the workpiece to ensure cor-
rect measurement.
●
Color/shiny surface boundary
Judgment error occurs when measuring workpieces of markedly different materials and
color. This error can be minimized by installing the Sensor Head with the line formed by
the emission and reception axes parallel to the boundary line on the workpiece as fol-
lows.
●
Installing near walls
Measurement error occurs when the Sensor Head receives light reflected from walls. If
a sufficient distance cannot be maintained between the Sensor Head and the wall,
measurement error can be reduced by installing the Sensor Head with the line formed
by the emission and reception axes parallel to the wall, and painting the wall with non-
reflective black paint.
Reception axis
Emission axis
Color/shiny
surface boundary
Right
Wrong
Right
Wrong