63
ZEN Image Display
Section 5-2
5-2
ZEN Image Display
CPU Unit and Expansion I/O Unit images are displayed according to
the configuration in the property settings, and input switches and
lamps are allocated to the I/O bits used in the ladder program.
Note
To display or hide the ZEN Image Window, click the
ZEN Image
Display
Button on the Toolbar.
Input switch specifications can be changed by right-clicking the input
switch symbol.
Input Switch Symbols
Present Value List
Display
Specifies whether or not the Present Value
List Window will be displayed.
Clock Display
Specifies whether or not the Clock Window
will be displayed.
Start/Stop
Simulator
Starts and stops the Simulator.
Input switch symbols
Display bit (D) display
Operation button symbols
Lamp symbols
Symbol
Input
specifications
Operation
Momentary: NO
condition
Normally OFF.
ON only when left mouse button is held
down.
Momentary: NC
condition
Normally ON.
OFF only when left mouse button is held
down.
Z184-E1-04.book Page 63 Thursday, November 20, 2008 4:25 PM