48
Operating and Stopping the ZEN
Section 3-6
3-6
Operating and Stopping the ZEN
This section describes how to operate and stop the ZEN from the
ZEN Support Software.
The ZEN must be connected and online and the project file opened
before these operations can be executed.
Precaution
Perform adequate safety checks before changing the operating mode
(RUN/STOP).
1,2,3...
1.
Select
ZEN(Z)/Change operating mode(M)/RUN(R)
from the
Menu Bar.
2.
Check that the Status Bar display changes from
STOP
to
RUN
.
3.
Select
ZEN(Z)/Change operating mode(M)/STOP(S)
from the
Menu Bar to stop ZEN operation. The Status Bar display will
change from
RUN
to
STOP
.
3-7
Monitoring Programs
3-7-1
Monitor
This section describes how to monitor programs being executed by
the ZEN.
The ZEN must be connected and online and the project file opened
before the programs can be monitored. The ZEN and the ZEN
Support Software programs must be the same before programs can
be monitored. Use the procedures outlined under
3-3 Transferring
Programs to the ZEN
(page 45),
3-4 Transferring Programs from the
ZEN
(page 46), and
3-5 Verifying Programs with the ZEN
(page 47)
to transfer and verify the programs.
1,2,3...
1.
Use the procedure outlined under
3-6 Operating and Stopping the
ZEN
(page 48) to start ZEN operation. Check that the Status Bar
display changes from
STOP
to
RUN
.
2.
Click the
Toggle Monitoring
Button on the Toolbar or select
ZEN(Z)/Monitor(O)
from the Menu Bar.
Z184-E1-04.book Page 48 Thursday, November 20, 2008 4:25 PM