![background image](http://html1.mh-extra.com/html/omron/tm-robot-tm12-series/tm-robot-tm12-series_hardware-installation-manual_743992056.webp)
Medium & Heavy Payload Series-Hardware Installation Manual TM12/14 Series Hardware Version: 3.2
56
Set to sink output type
Connect DO_COM terminal to the minus side of the power supply.
Figure 49: Set to Sink Output Type
Set to source output type
Connect DO_COM terminal to the plus side of the power supply.