Host Connections by RS-232C
Section 2-8
2-8
Host Connections by RS-232C
Connect NT20S-ST128 with an RS-232C Interface Unit installed to the host com-
puter with an RS-232C cable.
RS-232C connection allows a single NT20S to be connected to the host.
A computer or other control device with a built-in RS-232C interface is a suitable
host for connection to the NT20S.
2-8-1
Host Computer Communication Settings
Set the host communication conditions according to the following table.
Item
Setting
Baud rate
Set to the same baud rate as the NT20S: 2400, 4800, 9600,
19200
Data bits
7 bits/8 bits
Stop bits
1 bit/2 bits
Parity
Even, Odd, None
Flow control
RS/CS control
XON/XOFF control
None
Note:
Set the same communication conditions at the NT20S and Host.
Refer to the appropriate instruction manuals for the method of setting the Host
communication conditions.
Set to the maximum baud rate supported by both the NT20S and Host.
The communication condition settings of the NT20S-ST128 are set with the
RS-232C communication conditions memory switches. For details, refer to “Set-
ting RS-232C Communication Conditions” on page 82.
2-8-2
Connector Pin Arrangement
The RS-232C connection between the NT20S and Host is described below.
NT20S Interface Unit
The connector specification is described below.
Electrical characteristics: Conforms to EIA RS-232C specifications.
Signal direction: Signal input and output are relative to the host computer.
1
5
6
9
Summary of Contents for NT20S
Page 1: ...Cat No V020 E1 04 NT20S Programmable Terminal OPERATION MANUAL ...
Page 2: ...i ...
Page 3: ...ii ...
Page 4: ...iii NT series Programmable Terminal Operation Manual Revised August 1997 ...
Page 5: ...iv ...
Page 7: ...vi ...
Page 11: ...x ...
Page 19: ...xviii ...
Page 129: ...110 ...
Page 169: ...150 ...
Page 253: ...234 ...