30
Installation
Section 2-2
S
Parts used for connection
Caution:
For the connection to the power supply terminal block, twisted wires of 2 mm
2
or
greater cross sectional area and M3.5 size crimp terminals must be used.
Tighten the screws on the terminal block to a torque of 0.8N·m.
Otherwise fire may occur.
Fork type
Round type
7 mm or less
7 mm or less
[Recommended terminals]
Maker
Type
(fork type)
Type
(round type)
Applicable Wire
(stranded wire)
Japan Solderless Terminal MFG
2-YS3A
2-3.5
Fuji Terminal
2-YAS3.5
V2-S3.5
2.00 to 2.63 mm
2
Nichifu Terminal
2Y-3.5
2-3.5