![background image](http://html1.mh-extra.com/html/omron/ns/ns_programming-manual_743537415.webp)
Section 2 NS Series Functions
2-16 Broken-line Graphs
2-368
NS Series Programming Manual
No. Item
Details
1 Group
name
Sets the name of the broken-line graph group (up to 32 characters long; both one-byte
and two-byte are counted as one character).
2
Graph line list
Lists the graph lines registered in the broken-line graph group.
3 Add
To add a graph line, click the
Add
Button. The Line Setting (Broken-line Graph Group)
Dialog Box will be displayed. For details on adding a line, refer to
Line Setting
(Broken-line Graph)
.
Up to 256 lines can be set in a group.
4
Delete
To delete a graph line, select the row containing that line and click the
Delete
Button.
5 Set
To change a registered graph line’s settings, select the row containing the desired line
and click the
Set
Button. The Line Setting (Broken-line Graph Group) Dialog Box will be
displayed. For details on editing a line, refer to
Line Setting (Broken-line Graph)
.
6
Draw Value
Outside of the
Range
The following diagrams show the display when
Draw the value outside of range
is se-
lected.
Draw the value outside of range
selected:
Values outside the range will be displayed at the top of the graph.
Draw the values outside of range
not selected:
Values outside the range will not be displayed.
7 Storage
Type
Select the storage format from the pull-down list on the right. For details, refer to
2-8-4
Numeral Display and Storage Type (General Tab)
.
8
Monitor Points
Sets the number of points to monitor in the broken-line graph.
9
Read in batch
Select this option when performing batch reads.
If this option is not selected the broken-line graph will always display the present value.
10 Trigger
A batch read is performed when the specified communications address goes from OFF
to ON.
11
Operation
Complete Flag
Sets the address that will be turned ON by the system when the batch read is com-
pleted.
12
No. of Histories
Sets the number of graphs to be retained in the broken-line graph history.
When this value is set to 0, history data is not retained.
When the number of saved graphs exceeds this set value, the oldest history data will
be deleted.
13
Clear history
when address
changes to ON
The history data will be cleared when the specified communications address goes from
OFF to ON.
Summary of Contents for NS -
Page 2: ......
Page 12: ...Contents vi NS Series Programming Manual...
Page 46: ...Section 1 Overview 1 5 Procedure before Operation 1 33 NS Series Programming Manual...
Page 590: ...Section 3 Using PTs 3 12 Function Key Settings NS15 Only 3 35 NS Series Programming Manual...
Page 604: ...Section 4 Using Functions 4 1 Application 4 13 NS Series Programming Manual...
Page 640: ...Section 5 Troubleshooting and Maintenance 5 2 Error Messages 5 35 NS Series Programming Manual...
Page 680: ...Appendices Appendix 6 Additional NS Series Functions A 39 NS Series Programming Manual...
Page 682: ......
Page 683: ......