![background image](http://html1.mh-extra.com/html/omron/ns/ns_programming-manual_743537181.webp)
Section 2 NS Series Functions
2-9 Buttons
2-134
NS Series Programming Manual
No. Setting
Details
1 Maximum
limit
Sets the maximum limit. Select either value or indirect reference.
If the action type is
Increment/decrement
and
Return to the Minimum Value when the
Maximum Value is exceeded
is selected, the value will be returned to the minimum limit and
set if the maximum limit is exceeded.
Example If the Word Button is pressed at a current value of 998 at the following settings:
Maximum limit of 1,000, minimum limit of 0, increment/decrement set to 5, and
Return to the
Minimum Value when the Maximum Value is exceeded
not selected:
Stays at 998.
If
Return to the Minimum Value when the Maximum Value is exceeded
is selected: Writes
“0”.
2 Minimum
limit
Sets the minimum limit. Select either value or indirect reference.
If the action type is
Increment/decrement
and
Return to the Maximum Value when the
Minimum Value is exceeded
is selected, the value will be returned to the maximum limit and
set if the minimum limit is exceeded.
Example: If the Word Button is pressed at a current value of 3 at the following settings:
Maximum limit of 1,000, minimum limit of 0, increment/decrement set to -5, and
Return to the Maximum Value when the Minimum Value is exceeded
is not selected: Stays
at 3.
If
Return to the Maximum Value when the Minimum Value is exceeded
is selected:
Writes “1000”.
The setting ranges for maximum and minimum limits depend on the
Numeral types
set on the General
Tab Page. If a value is set under
Value
that exceeds the range set under
Numeral types
and the OK
Button is pressed, a message stating that the setting range has been exceeded will be displayed and
the setting will not be made.
Flicker Tab Page
Make flicker settings to make the functional object flicker (flash). Refer to
Flicker
under
2-8 Common
Functional Object Functions
for details.
Write Tab Page
Use the write to display a confirmation dialog box before writing values to a write address. The confir-
mation message can be changed. Refer to
Write Settings
under
2-8 Common Functional Object Func-
tions
for details.
Password Tab Page
Set a password for when buttons are pressed. Five passwords of up to 16 characters each can be set.
One password can be requested for each object. Refer to
Passwords
under
2-8 Common Functional
Object Functions
for details.
Control Flag Tab Page
Control flags control the input and display of functional objects. Use control flags to enable display or
input when the contents of an address turn ON or OFF. Refer to
Control Flags
under
2-8 Common
Functional Object Functions
for details.
Macro Tab Page
Macros can be specified for Word Buttons.
Macros executed by the following triggers can be registered.
Trigger Details
Touch ON
Executes macro when the button is pressed.
Touch OFF
Executes macro when the button is released.
Refer to the CX-Designer’s
NS-series Macro Reference
for information on setting macros.
Size/position Tab Page
Displays and sets the functional object size and position. Refer to
Size/Position
under
2-8 Common
Functional Object Functions
for details.
Summary of Contents for NS -
Page 2: ......
Page 12: ...Contents vi NS Series Programming Manual...
Page 46: ...Section 1 Overview 1 5 Procedure before Operation 1 33 NS Series Programming Manual...
Page 590: ...Section 3 Using PTs 3 12 Function Key Settings NS15 Only 3 35 NS Series Programming Manual...
Page 604: ...Section 4 Using Functions 4 1 Application 4 13 NS Series Programming Manual...
Page 640: ...Section 5 Troubleshooting and Maintenance 5 2 Error Messages 5 35 NS Series Programming Manual...
Page 680: ...Appendices Appendix 6 Additional NS Series Functions A 39 NS Series Programming Manual...