background image

 

 

IP/V24 WALLBOARD  

2 x 16 digits 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

TECHNICAL 

 

MANUAL 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
AUTHOR 

 

 

 

 

DATE  

 

 

    REFERENCE 

 

 

V. Bafour  

 

 

 

 

23/01/2008 

 

 

 

D0503002 

 

Summary of Contents for IP

Page 1: ...IP V24 WALLBOARD 2 x 16 digits TECHNICAL MANUAL AUTHOR DATE REFERENCE V Bafour 23 01 2008 D0503002 ...

Page 2: ...D CONFIGURATION 7 5 4 1 CCS A4400 IP Mode Configuration 8 5 4 2 CCS A4400 V24 Mode Configuration 8 5 4 3 12 digit ACD CCD A4400 V24 Mode Configuration 9 5 4 4 8 digit A4300 V24 Mode Configuration 10 5 5 WALLBOARD CONNECTIONS 11 5 5 1 Ethernet Connections 11 5 5 2 V24 Connections 11 5 5 3 2x16 Wallboard Connection in Cascade behind Ethernet 12 5 5 4 2x16 Wallboard Connection in Cascade behind V24 1...

Page 3: ...o not install the wallboard in any environment where pollution exceeds level 2 2 2 Power Source The wallboard must be installed by a qualified staff The power socket must be installed near the wallboard and easily reachable Otherwise a quickly accessible shutoff device must be integrated into the fixed installation 2 3 Maintenance Unplug the wallboard before any maintenance operation Do not use an...

Page 4: ...ion V24 or current loop Rate 600 1 200 2 400 4 800 or 9 600 Bauds Format 8N2 Up to eight 2x16 wallboards can be connected through one single serial link Display modes Steady flashing Display colors Red green orange Buzzer Power Supply 100 240 V 0 5 A 47 63 Hz Installation Class II Equipment can be connected to TT or TN supply network only Class I equipment connected through IEC83 compliant 2P T po...

Page 5: ...onous serial output for the parallel connection of up to seven additional 2x16 wallboards The wallboard can be connected Directly behind the A4300 V24 Directly behind A4400 V24 for ACD CCD applications Behind the CSS control panel V24 managed by the Wall Board Manager application Through the local Ethernet network to the CSS control panel managed by the Wall Board Manager application 4 1 Synopsis ...

Page 6: ...e wall attachment 3 Complete the configuration micro switchs 4 Complete the connections 5 2 List of Supplies Qty Reference Designation 1 P3540200 2x16 wallboard 1 C2130008 Mounting foot 1 C1800208 Female mains plug 1 C1800125 Screw on 4 way female connector 1 C2000010 Crossed Ethernet cable Wallboard 1 Wallboard 2 Wallboard 8 Current Loop V24 Current Loop 4300 4400 PC CCS WBM ...

Page 7: ...ntres 310mm Screws Ø 3mm Outdistance minimum ceiling 200mm 5 4 Wallboard Configuration The wallboard operating mode is set up using SW1 SW8 micro switchs that can be accessed through an opening on the top panel of the wallboard Micro switchs are read when the wallboard is started SW6 and SW7 show the mode SW1 SW5 show related settings and SW8 is not used SW8 ON SW1 ...

Page 8: ... Read only On yes IP settings are configured while connecting to the wallboard via a Web browser See Section Commissioning IP Setting Management 5 4 2 CCS A4400 V24 Mode Configuration SW8 SW7 SW6 SW5 SW4 SW3 SW2 SW1 Off Off On Off Off Off 0 Off Off On 1 Off On Off 2 Off On On 3 On Off Off 4 On Off On 5 On On Off 6 On On On 7 Wallboard Address Off 4800 On 9600 Rate Bauds Off 3 On 10 Buzzer Duration...

Page 9: ...ff Off Off 0 Off Off On 1 Off On Off 2 Off On On 3 On Off Off 4 On Off On 5 On On Off 6 On On On 7 Wallboard Address Off Off ACD Off On CCD French 1 On Off CCD French 2 On On CCD English Line 1 Display Text Displayed in Line 1 1 16 A P P C O N V P A R D I S ACD A P P C O N V P A R D I S CCD French 1 A F F L I B C O N V P A R CCD French 2 Q S E F F P A R K D I S CCD English ...

Page 10: ...f 600 Rate Bauds Off On 1200 On Off 2400 On On 4800 Off French Language On English Off M A4300 Type On L Text Displayed in Line 1 1 16 A P P C O N V P A R D I S A4300 M A F F L I B C O N V P A R A4300 L Forward Messages Displayed in Line 1 1 16 R E N V O I A U T O French R E N V O I G U I D E S R E N V O I p q m c d u F O R W A R D A U T O English F O R W A R D G U I D E S F O R W A R D p q m c d ...

Page 11: ...ds in cascade are linked in current loop behind the first wallboard connected to the Ethernet or V24 The distance between the first and last wallboards can not exceed 500m 5 5 1 Ethernet Connections Use the crossed Ethernet cable when the wallboard is connected to a PC directly To comply with EMC rules the cable type must be FTP or STP 5 5 2 V24 Connections Pin 1 SG Pin 2 TD To comply with EMC rul...

Page 12: ...OARD 2 x 16 digits TECHNICAL MANUAL D0503002 23 01 2008 Page 12 18 5 5 3 2x16 Wallboard Connection in Cascade behind Ethernet RJ45 Ethernet Cable 1 2 3 4 1 2 3 4 1 2 3 4 Wallboard 1 Wallboard 2 Wallboard 8 500m max ...

Page 13: ...2 x 16 digits TECHNICAL MANUAL D0503002 23 01 2008 Page 13 18 5 5 4 2x16 Wallboard Connection in Cascade behind V24 V24 Current Loop Connection 1 2 3 4 SG TD 1 2 3 4 1 2 3 4 Wallboard 1 Wallboard 2 Wallboard 8 500m max ...

Page 14: ...green This allows visually checking that every wallboard dot works properly 6 3 IP Setting Management IP setting management only applies if the wallboard is set up in IP mode see configuration IP settings can be accessed from a PC A Web browser can be used to connect to the wallboard s IP address At power on the wallboard s IP address is displayed in the second line 6 3 1 First Commissioning Follo...

Page 15: ...NUAL D0503002 23 01 2008 Page 15 18 Windows 98 example Change network neighborhood properties Windows NT example 4 With a Web browser connect to the wallboard s IP address http 10 0 0 88 for the default address to open the wallboard s setup page ...

Page 16: ...ds after validation Internet Explorer example Address Wallboard address default 0 Baud rate Output rate of the serial connection default 9 600 Buzzer duration Duration of the buzzer in seconds default 3 IP address IP address default 10 0 0 88 Net mask Sub network mask default 255 0 0 0 Gateway Gateway address To be filled in to access the settings from another network default blank ...

Page 17: ...ollows 1 Make sure that micro switch SW5 is Off read only 2 Use a PC connected to the same network as the wallboard 3 Using a Web browser connect to the wallboard s IP address 4 Change the settings Entering new settings causes the wallboard to be reset a few seconds after validation 5 Switch on SW5 to prevent settings from being changed Wallboard 10Mbit Ethernet ...

Page 18: ...e Internet In the browser settings remove the proxy server or specify that the proxy server should not be used to connect to the wallboard s IP address Cause Solution Error in the sub network mask or gateway address Turn the wallboard off install micro switch SW4 turn the wallboard back on and remove micro switch SW4 This allows resetting the wallboard to its default parameters IP Address 10 0 0 8...

Reviews: