![background image](http://html1.mh-extra.com/html/omron/ld-platform/ld-platform_user-manual_743974068.webp)
68
LD Platform OEM User's Guide
11970-000 Rev H1
6.2 Payload Bay Connections
Light Pole
Connector type
Mini-Fit
®
3 x 2
Use
Light tower (user-supplied)
Pin No.
Designation
Notes
1
GND
Cable shield
2
LIGHT_P1
Red
3
LIGHT_P2
Yellow or orange
4
VBAT_IO_OUT4 VBAT @ 0.5A Max (shared with DIO)
5
LIGHT_P3
Green
6
LIGHT_P4
Buzzer
VBAT_IO_OUT4
4
LIGHT_P1_N
2
LIGHT_P2_N
3
LIGHT_P3_N
5
LIGHT_P4_N
6
GND
1
(equivalent
circuit)
Typical user load
Wiring terminal block
Standard Equipment
User-Supplied Equipment
Figure 6-6. Sample Light Pole Diagram