50
LD Platform OEM User's Guide
11970-000 Rev H1
4.4 Supplemental Information
The limits and defaults for these parameters are listed in the following table.
Parameter
Default
Min
Max
AbsoluteMaxTransVel (LD-60)
1800
1
2500
AbsoluteMaxTransVel (LD-90)
1350
1
2500
AbsoluteMaxTransNegVel (LD-60)
-280
-2500
a
-1
AbsoluteMaxTransNegVel (LD-90)
-210
-2500
a
-1
AbsoluteMaxTransAccel
1000
1
2000
AbsoluteMaxTransDecel
2000
1
2000
AbsoluteMaxRotVel
180
1
180
AbsoluteMaxRotAccel
360
1
360
AbsoluteMaxRotDecel
360
1
360
a: Although the Min value, in software, is -2500, the hardware safety system on the platform will
generate a fault if the velocity is anything from -300 to -2500 mm/s.
4.4 Supplemental Information
Laser Setup
For most installations, the defaults for the lasers should be appropriate, and will not require
any user adjustment.
The specific parameters for these lasers will come in the model config file that ships on the
unit, or can be provided on request if needed.
l
Laser_1 Settings are for the main scanning laser (S300), used both for safety and loc-
alization.
l
Laser_2 Settings are for the low front laser (TiM).
l
Laser_3 Tilted and Laser_4 Tilted are for the side lasers (TiM).