64
LD Platform OEM User's Guide
11970-000 Rev H1
6.2 Payload Bay Connections
Standard Equipment
User-Supplied Equipment
Outputs 1-16
Typical User Loads
VBAT_IO_OUT1
VBAT_IO_OUT4
21
OUTPUT_1
22
OUTPUT_2
23
OUTPUT_3
24
OUTPUT_4
25
OUTPUT_5
36
OUTPUT_16
GND
Load
41
GND
44
Load
(equivalent
circuit)
Wiring Terminal Block
37
Load
40
Figure 6-4. Typical Digital Output Wiring Example
Analog I/O
Connector type
HDB15M
Pin No.
Designation
Notes
1
ANALOG_IN1
0 – 10 V Range
2
ANALOG_IN2
0 – 10 V Range
3
ANALOG_IN3
0 – 10 V Range
4
ANALOG_IN4
0 – 10 V Range
5
ANALOG_IN5
0 – 30 V Range
6
ANALOG_IN6
0 – 30 V Range
7
ANALOG_IN7
0 – 30 V Range
8
ANALOG_IN8
0 – 30 V Range
9
ANALOG_OUT1 0 – 20 V Range
10
ANALOG_OUT2 0 – 20 V Range
11
ANALOG_OUT3 0 – 20 V Range
12
ANALOG_OUT4 0 – 20 V Range
13, 14, 15 GND
l
The 0-10 V analog inputs have an input impedance of about 35 kΩ.
l
The 0-30 V analog inputs have an input impedance of about 110 kΩ.