3 - 9
3 Operation
Grid Connect Photovoltaic Inverter KP100L-OD-
USER’S MANUAL
3-
4 S
tat
e Disp
lay
3
9
3-4
State Display
The display according to the state of the KP100L is done. State Display includes Normal Display and Error
Display.
Normal Display
When the error doesn't occur in the KP100L, the follow content corresponding to the state of the KP100L is
displayed.
The Display [2] shows data and the state corresponding to the state of KP100L at that time.
The Display [3] shows the measurement value. Select the measurement value that you want to display by
pushing the "<<" or ">>" key. The displayed item is changed every 0.5 seconds when you keep pushing the "<<"
or ">>" key. The Display [1] shows the item name of the data displayed in the Display [3].
Refer to the follow table for the item that you can select.
State
Display (example)
Content of Date
Countdown
30s
Start-up delay time
Start waiting
Standby
-
Running
1.23kW
AC Power
Stopping
OFF
-
Item name
Measurement Value
Data display form
Pac
AC Power(L1 phase/L2 phase/L3 phase)
1.23/1.23/1.23kW
Pdc1/2/3
DC Power (DC1/DC2/DC3)
1.23/1.23/1.23kW
Vac
Grid Voltage(L1 phase/L2 phase/L3 phase)
230/230/230V
Freq
Grid Frequency
50.0Hz
Iac
AC Current (L1 phase/L2 phase/L3 phase)
12.3/12.3/12.3A
Vdc1/2/3
DC Voltage (DC1/DC2/DC3)
400/400/400V
Idc1/2/3
DC Current (DC1/DC2/DC3)
12.3/12.3/12.3A
E-today
Daily energy production
123.4kWh
H-total
accumulated operation time
123456hr
E-total
Total Periodic Energy (accumulated energy from time user reset) E-total can be reset
by user. Refer to section "User Setting" in "3-5" [15] Clear of Total Periodic Energy
12345kWh
Pac 3.69kW
Pdc1/2/3 3.69kW
1.28/1.28/1.28kW
<<
<<
>>
>>
Pac 30s
Pac Standby
Countdown
end
preparation
completion
Pdc1/2/3 30s
<<
<<
>>
>>
Pdc1/2/3 Standby
0.00/0.00/0.00kW
0.00/0.00/0.00kW
<<
<<
>>
>>
Start waiting Display
Countdown Display
Running Display
0.00/0.00/0.00kW
0.00/0.00/0.00kW
1.23/1.23/1.23kW
Summary of Contents for KP100L-OD - 12-2010
Page 18: ...17 Grid Connect Photovoltaic Inverte KP100L OD USER S MANUAL ...
Page 21: ...20 Grid Connect Photovoltaic Inverte KP100L OD USER S MANUAL ...
Page 33: ...1 Overview 1 12 Grid Connect Photovoltaic Inverte KP100L OD USER S MANUAL ...
Page 63: ...2 Design 2 30 Grid Connect Photovoltaic Inverte KP100L OD USER S MANUAL ...
Page 103: ...4 Maintenance Operations 4 12 Grid Connect Photovoltaic Inverter KP100L OD USER S MANUAL ...
Page 113: ...6 After Sales Service 6 4 Grid Connect Photovoltaic Inverter KP100L OD USER S MANUAL ...
Page 117: ...7 Specifications 7 4 Grid Connect Photovoltaic Inverter KP100L OD USER S MANUAL ...
Page 125: ...A Appendix A 8 Grid Connect Photovoltaic Inverter KP100L OD USER S MANUAL ...