Grid Connect Photovoltaic Inverte KP100L-OD-
USER’S MANUAL
2-4 Wiring
2
(5)-3 AUX_IN
Connect the wire to 1 : , 2 : AUX_IN- of AUX terminal block(TB402). When you connect the
wire, insert the wire while you push the black button of TB402 and release the button.
Note: Note the wrong wiring of the signal wire, and the catch of the insulating coating.
(6) Tighten the cap of the cable clamp surely.
If the tightening is insufficient, the effect of the waterproof is not achieved.
Attachment of cover foreside R
Mount the cover foreside R by the 4 screws surely (tightening torque : 1.5 to1.7N
m)
When tightening the screws is insufficient, the effect of the waterproof is not achieved.
TB402
TB401
1
2
3
4
5
6
7
8
9
10