Useful Functions for Operation
FZ3 User's Manual
"Save to file" setting example and save destination
Example of setting
Save destination
●
Folder name: USBDisk
●
Prefix: image_
●
"Switch saving folder by scene":
Checked
●
"Switch saving folder by judge":
Checked
Saving will be performed as follows for the settings example
on the left
●
OK image save destination:
\USBDisk\S000-000\OK\image_(Measurement ID).IFZ
●
NG error image save destination:
\USBDisk\S000-002\NG\image_(Measurement ID).IFZ
4.
Set the image logging priority conditions.
This setting is only valid when "Save to file" is selected in the image logging saving
conditions.
When the measurement tact time is short, time lag may occur with writing from the controller
memory to the RAMDisk or USBDisk and temporary absences of free space in the controller
memory may occur.Select whether logging or measurement has priority at these times.
Setting item
Set value
[Factory
default]
Description
Logging
priority
[Logging]
When there is no free capacity in the controller memory, subsequent
measurement cannot be received until free capacity becomes
available.
All measurement target images are logged, but the measurement tact
time becomes longer.
Measurement
Measurement will continue even if there is no free capacity in the
controller memory.New logging is not performed until free capacity
becomes available in the controller memory.
The measurement tact time is maintained, but some measurement
may not be logged.
5.
Set the data logging conditions.
The data format is set with the processing item "Data Logging".