133
Command (PLC to Controller)
Command area
top channel
Command
code
Bit
Description
15-12
11-8
7-4
3-0
+2
1030
0001
0000
0011
0000
Set command
codes.
+3
0010
0000
0000
0001
0000
Response (Controller to PLC)
Response
area
top channel
Bit
Description
15-12
11-8
7-4
3-0
+2
0001
0000
0011
0000
Command code
Store response target command codes.
+3
0000
0000
0001
0000
+4
0000
0000
0000
0000
Response code
Command execution result
OK: 0 (0000 0000)
NG: -1 (FFFF FFFF)
+5
0000
0000
0000
0000
Clearing Measurement Values
Clears all measurement values.
Command (PLC to Controller)
Command area
top channel
Command
code
Bit
Description
15-12
11-8
7-4
3-0
+2
2010
0010
0000
0001
0000
Set command
codes.
+3
0010
0000
0000
0001
0000
Response (Controller to PLC)
Response
area
top channel
Bit
Description
15-12
11-8
7-4
3-0
+2
0010
0000
0001
0000
Command code
Store response target command codes.
+3
0000
0000
0001
0000
+4
0000
0000
0000
0000
Response code
Command execution result
OK: 0 (0000 0000)
NG: -1 (FFFF FFFF)
+5
0000
0000
0000
0000
Saving in Controller
Stores the current system data and scene group in the controller.