Environment
114
Setting the System Operation Environment
FZ3 User's Manual
Serial (Ethernet)
●
[Normal]
●
Normal (Fxxx series
method)
●
PLC Link
(SYSMAC CS/CJ/CP/
One)
Sets the communication module.
Serial/Ethernet
Normal/Normal (Fxxx series method):
External devices are communicated with
using non-procedure communications. For
the differences between Normal and Normal
(Fxxx series method), see the note below.
PLC Link: Communication is performed via
a link area with the PLC.
Parallel
Standard Parallel I/O: Communication is
performed via a standard parallel interface.
Serial (RS-232C/
RS-422)
●
[Normal]
●
Normal
(Fxxx series method)
●
PLC Link
(SYSMAC CS/CJ/CP/
One)
Parallel
[Standard Parallel I/O]
3.
Tap [OK].
Settings are confirmed and the Startup Setting window closes.
Note
●
About "Normal (Fxxx series method)"
With the "Normal (Fxxx series method)" communication method, the OK response timing in relation to
MEASURE commands is different from that of the "Normal" communication method.
"Normal (Fxxx series method)" communication method
"Normal" communication method
MEASURE
Measurement result
OK
MEASURE
OK
Measurement result
Setting the RUN Window Display [RUN mode View Setting]
The layout of display contents and size of characters can be set.
1.
On the Main screen, tap the [System] menu - [Controller] - [RUN mode view setting].
The current RUN window mode is displayed.To change the mode, specify the mode in System/
Controller/Select RUN mode .
2.
Set items to be displayed.
3.
Set the layout as required.