
7
External
Reference
Tables
244
Branch
FZ3 User's Manual
Branch
Conditional Branch
No.
Data name
Set/Get
Data range
0
Judge
Get
0: No judgement (unmeasured)
1: Judgement result OK
-1: Judgement result NG
5
Expression A result
Get
Maximum 256 characters (result of calculation selected in
expression A)
6
Expression B result
Get
Maximum 256 characters (result of calculation selected in
expression B)
7
Comparison result
Get
0: NO
1: YES
8
Destination unit No. Get
0 to 32767
120
Condition type
Set/Get
0: A = B
1: A < = B
2: A < B
3: A > = B
4: A > B
121
YES branch
destination unit No.
Set/Get
-1: End processing
0 to 32767: Unit No.
122
NO Destination unit
No.
Set/Get
-1: End processing
0 to 32767: Unit No.
DI Branch
No.
Data name
Set/Get
Data range
0
Judge
Get
0: No judgement (unmeasured)
1: Judgement result OK
-1: Judgement result NG
5
DI input No.
Get
No. used to indicate DI input (00000 to 11111)
6
Unit No
Get
Unit number at destination corresponding to DI input
120 to
151
Destination Unit
No. 0 -
Destination Unit
No. 31
Set/Get
-1: End processing
0 to 9999: Unit No.
Acesst 1.0 6251194