6
M
eth
od
s
fo
rC
on
ne
ctin
g
an
d
C
om
m
un
ica
tin
g
w
ith
E
xte
rn
al
D
ev
ice
s
FZ3 User's Manual
Communicating through Serial Communication (PLC Link)
131
+12
DATA6
Output data 6
+13
+14
DATA7
Output data 7
+15
Signal
Signal name
Function
DATA0-7
Output data
0-7
The data set in the output processing items is output.
When there are multiple processing items, data is overwritten to this area while
"handshaking" is performed.
Command Control (PLC Link)
This section explains each command used in PLC Link.
Measurement control command
Command code
Function
References
Lower CH
Upper CH
0010
1010
Performs measurement one time
0010
1020
Start continuous measurement
0010
1030
Complete continuous measurement
0010
2010
Clear measurement values
0010
3010
Save in controller
0010
F010
Restart the controller
Scene control command
Command code
Function
References
Lower CH
Upper CH
0020
1000
Acquire scene No.
0020
2000
Acquire scene group No.
0030
1000
Switch scenes
0030
2000
Switch the scene group No.
Settings acquisition/change command
Command code
Function
References
Lower CH
Upper CH
0040
1000
Acquire unit data
0040
2000
Acquire the current date and time
0040
3000
Acquire system version information
0050
1000
Set unit data
0050
2000
Set the date/time
Executing Measurement
Executes measurement one time.
Acesst 1.0 6251194