3
Performing
Test
Measurement/Starting
Operation
76
Useful Functions for Operation
FZ3 User's Manual
Useful Functions for Operation
Remeasuring Saved Images
Images from when measurement, including test measurement, was performed can be
saved.Remeasurement can be performed with saved images after conditions are adjusted in order to
check whether the adjustment is appropriate.
The logging function is used for saving images.
Reference:
Setting Logging Conditions [Logging Setting] (p.84)
Images that can be remeasured include images saved in the controller and images saved in USB
memory.
1.
In the Control area of the Main screen, tap [Test measurement].
2.
Tap [Select image].
The Select Image window is displayed.
3.
Tap [...] and select the file to display.
Setting item
Description
File
Specify images saved in the USB memory or in the RAMDisk.
Logging image
Specify images that are logged in the controller memory.
4.
The selected image is displayed at the lower left of the FileExplorer screen.
When there are multiple camera images in a file, as for a logging image when multiple cameras
are connected, use the "<<" and ">>" buttons to switch images.
Acesst 1.0 6251194