4--1--2
Terminals
E5AF-A20 terminal identifications and functions are shown below.
14
1
13
25
Terminal no.
Signal name
Signal
direction
Description
1
DSL1
Input
Data select code 2
0
2
DSL2
Input
Data select code 2
1
3
DSL3
Input
Data select code 2
2
4
DSL4
Input
Data select code 2
3
5
DSL5
Input
Data select code 2
4
6
DSL6
Input
Data select code 2
5
7
------
------
------
8
WD1
Input
Write data 2
0
9
WD2
Input
Write data 2
1
10
WD3
Input
Write data 2
2
11
WD4
Input
Write data 2
3
12
VAL
Input
Effective signal
13
GND
------
Output side power supply 0 V
14
RD1
Output
Read data 2
0
15
RD2
Output
Read data 2
1
16
RD3
Output
Read data 2
2
17
RD4
Output
Read data 2
3
18
BUSY
Output
BUSY signal
19
------
------
------
20
------
------
------
21
------
------
------
22
------
------
------
23
24 VDC
------
24 VDC output side power supply (must be supplied from an external
power supply)
24
24 VDC
------
24 VDC output side power supply (common with terminal 23)
25
GND
------
24 VDC output side power supply (common with terminal 13)
Plug:
XM4A-2521 (OMRON) or equivalent.
Hood:
XM2S-2511 (OMRON) or equivalent.
Connectors
Section 4--1
Summary of Contents for E5AF
Page 1: ...E5AF E5EF Fuzzy Temperature Controller Operation Manual Produced July 1992 ...
Page 2: ... ...
Page 4: ... ...
Page 5: ... 0 1 2 3 0 3 3 4 5 6 7 1 8 6 5 9 6 5 9 8 ...
Page 6: ... 0 1 2 ...
Page 8: ... 8 2 8 ...
Page 10: ... The Heater Burnout Detection Models are shown below E5AF AH E5EF AH Section 1 2 ...
Page 11: ... 8 2 8 1 8 2 8 8 ...
Page 17: ... 8 2 8 8 8 8 2 8 8 5 0 1 2 3 0 3 3 4 5 5 5 ...
Page 47: ... 8 2 8 8 1 8 5 6 7 8 1 8 0 6 5 9 6 5 2 6 5 2 0 6 6 5 9 5 8 ...
Page 71: ... 8 2 8 8 8 8 5 8 ...
Page 78: ... 0 1 0 2 3 1 1 4 0 1 1 1 1 5 5 6378 6 78 5 0 2 10 0 00 0 0 9 4 9 1 3 04 1 0 0 0 2 ...
Page 79: ... 1 6 8 6 8 6 58 0 1 4 0 0 2 1 1 1 1 14 4 4 4 1 1 1 9 1 1 0 0 1 ...
Page 80: ... 14 6 8 14 4 1 4 5 0 1 0 1 0 ...