![background image](http://html1.mh-extra.com/html/omron/componett-e3nw-crt/componett-e3nw-crt_user-manual_742285090.webp)
88
Sec
tion 5
App
e
ndic
e
s
E3NW-CRT
User’s Manual
Section 5
Command Descriptions and Data Formats
●
Eco Mode
This command sets the Eco Mode of the Sensor Amplifier Unit that corresponds to the
specified unit number.
●
Key Lock Setting
This command sets the key lock of the Sensor Amplifier Unit that corresponds to the
specified unit number.
●
Flash Display Setting
This command sets the Flash Display Setting of the Sensor Amplifier Unit that
corresponds to the specified unit number.
●
Cancel Flash Display Setting
This command cancels the Flash Display of the Sensor Amplifier Unit that corresponds
to the specified unit number.
●
Hysteresis Width Setting
This command sets the Hysteresis Width of the Sensor Amplifier Unit that corresponds
to the specified unit number.
●
Hysteresis Width 1
This command sets Hysteresis Width 1 of the Sensor Amplifier Unit that corresponds to
the specified unit number.
Bit
Description
Data
00
Eco Mode
0: Eco Mode OFF
1: Eco Mode ON
2: Eco Mode LO
02 to 31
No applicable data
Always 0
Bit
Description
Data
00
Key Lock Setting
0: Key lock OFF
1: Key lock ON
01 to 31
No applicable data
Always 0
Bit
Description
Data
00
Hysteresis Width Setting
0: Standard
1: User setting
01 to 31
No applicable data
Always 0
Bit
Description
Data
00 to 31
Hysteresis Width 1
Data range: 0 (00000000 hex) to 9999 (0000270F hex)