CompoNet Remote I/O Communications
• Communications Error with Sensor Amplifier Unit:
This flag turns ON when the registered number of connected Sensors does not match
the number of Sensors available for communications, or when communications with a
Sensor Amplifier Unit fails after a connection with the Sensor Amplifier Unit has been
established.
■
I/O Mode 2
This mode uses the I/O area to check the Sensor Amplifier Unit’s detection level and
change settings.
This enables you to change Sensor Amplifier Unit settings even when connected to a
master that does not support explicit messages.
In this mode, you can connect a maximum of 16 Sensor Amplifier Units.
The I/O area that is allocated in the master consists of six input words and six output
words.
Input: Word m
Input: Word m + 1
Bit
Description
Bit
Description
00
Unit 1 ON/OFF output data 1
00
Unit 9 ON/OFF output data 1
01
Unit 1 ON/OFF output data 2
01
Unit 9 ON/OFF output data 2
02
Unit 2 ON/OFF output data 1
02
Unit 10 ON/OFF output data 1
03
Unit 2 ON/OFF output data 2
03
Unit 10 ON/OFF output data 2
04
Unit 3 ON/OFF output data 1
04
Unit 11 ON/OFF output data 1
05
Unit 3 ON/OFF output data 2
05
Unit 11 ON/OFF output data 2
06
Unit 4 ON/OFF output data 1
06
Unit 12 ON/OFF output data 1
07
Unit 4 ON/OFF output data 2
07
Unit 12 ON/OFF output data 2
08
Unit 5 ON/OFF output data 1
08
Unit 13 ON/OFF output data 1
09
Unit 5 ON/OFF output data 2
09
Unit 13 ON/OFF output data 2
10
Unit 6 ON/OFF output data 1
10
Unit 14 ON/OFF output data 1
11
Unit 6 ON/OFF output data 2
11
Unit 14 ON/OFF output data 2
12
Unit 7 ON/OFF output data 1
12
Unit 15 ON/OFF output data 1
13
Unit 7 ON/OFF output data 2
13
Unit 15 ON/OFF output data 2
14
Unit 8 ON/OFF output data 1
14
Unit 16 ON/OFF output data 1
15
Unit 8 ON/OFF output data 2
15
Unit 16 ON/OFF output data 2