87
E3NW-CRT
User’s Manual
Sec
tion 5
App
e
ndic
e
s
Section 5
Command Descriptions and Data Formats
●
Display Switch
This command sets the display on the Sensor Amplifier Unit that corresponds to the
specified unit number.
“Detection level” in this table is the amount of incident light to the Sensor Amplifier Unit
or the amount of displacement.
* The display that is set in bits 00 to 03 is displayed when an Amplifier Unit operation is
performed after setting up the Solution Viewer.
Example: Set the Display Switch Setting to 00010000 hex, change to the Solution
Viewer display, and perform an Amplifier Unit operation. The threshold
value/detection level [Std] will be displayed.
* The Solution Viewer does not apply to the SA0.
●
Reversed Display
This command reverses the display on the Sensor Amplifier Unit that corresponds to
the specified unit number.
●
Channel Display
This command sets the channel display of the Sensor Amplifier Unit that corresponds
to the specified unit number.
●
Clear Channel Display
This command clears the channel display of the Sensor Amplifier Unit that corresponds
to the specified unit number.
Bit
Description
Data
00
Display Switch
0: Threshold value/detection level [Std]
1: Detection level margin for the threshold value [PEr]
2: Incident light peak minimum value and interrupted light
bottom maximum value [P-b]
3: Bar display [bAr]
4: Peak detection level [PEAK]
5: Channel number and detection level [ch]
6: Change finder [CFdr] (FA0/LA0)
01
02
03
04 to 07
No applicable data
Always 0
09
Display Switch
0: Solution Viewer OFF
1: Solution Viewer ON
10 to 31
No applicable data
Always 0
Bit
Description
Data
00
Reversed Display
0: Reversed display OFF
1: Reversed display ON
01 to 15
No applicable data
Always 0