E3NW-CRT
User’s Manual
Section 5
Command Descriptions and Data Formats
●
Threshold Setting 2
This command reads or writes Threshold Value 2 of the Sensor Amplifier Unit that
corresponds to the specified unit number.
Threshold Value 2 is the high threshold value in area detection mode.
The data is given as the two’s complement of a 4-byte (8-digit) hexadecimal value.
Do not execute any write instructions that exceed the allowable data range for each model.
●
Sensor Status
This command reads the sensor status of the Sensor Amplifier Unit that corresponds to
the specified unit number.
●
Zero Reset Level
This command reads the zero reset level of the Sensor Amplifier Unit that corresponds
to the specified unit number.
The data is given as the two’s complement of a 4-byte (8-digit) hexadecimal value.
Bit
Description
Data
00 to 31
Threshold Setting 2
Data range:
−
1999 (FFFFF831 hex) to 9999 (0000270F hex)
Bit
Sensor status
00
Normal operation
(For normal operation, this bit is always 1. If any bit after 08 changes to 1, this bit changes to 0.)
01
DPC status (DPC ON: 1, ST OFF: 0)
02
Smart Tuning status (ST ON: 1, ST OFF: 0)
03 to 07
Always 0 (not used).
08
DPC error (FA0/LA0)
09
EEPROM error (all models)
10
Load short-circuit error (all models)
11
Head-related error (SA0)
12 to 31
Always 0 (not used).
Bit
Description
Data
00 to 31
Zero Reset Level
Data range:
−
9999 (FFFFD8F1 hex) to 9999 (0000270F hex)