Section 5
Command Descriptions and Data Formats
●
One-point Tuning
This command executes one-point tuning for the Sensor Amplifier Unit that
corresponds to the specified unit number and output number.
This must be performed at least 3 seconds after a full auto tuning setup is executed
with no workpiece.
●
Flashing
This command executes flashing for the Sensor Amplifier Unit that corresponds to the
specified unit number.
●
Clear Flashing
This command clears flashing for the Sensor Amplifier Unit that corresponds to the
specified unit number.
●
Initialize
This command initializes the Sensor for the Sensor Amplifier Unit that corresponds to
the specified unit number.
Do not press the button on the Unit to initialize the Sensor during operation. When in
operation, always use this command to perform Sensor initialization.
Sensor initialization will not reset the Channel Display, Display Flash, Light OFF, and
Flashing Settings.
●
Self-Trigger Level
This command sets the Self-Trigger Level of the Sensor Amplifier Unit that corresponds
to the specified unit number.
The data is given as the two’s complement of a 4-byte (8-digit) hexadecimal value.
●
Tuning without a Workpiece
The command executes tuning without a workpiece for the Sensor Amplifier Unit that
corresponds to the specified unit number and output number.
Tuning for the first point of two-point tuning must be executed first and there must be no
workpiece.
Bit
Description
Data
00 to 31
Self-Trigger Level
Data range: -1999 (FFFFF831 hex) to 9999 (0000270F hex)