Chapter 2 Installation & Wiring
2-2 Wiring
3D TOF Sensor Module B5L User's Manual (No. E596)
To power off
This section describes the operation flow of this product from the end of operation to
power-off
.
・
Power-OFF sequence
Execute the distance measurement stop command and turn off the power after the
distance measurement is stopped.
Refer to "3-2 Basic Process on Host" for details.
Note: If the power supply voltage is dropped to 0V, do not perform the start-up sequence immediately,
but wait for 5 seconds or more before turning the power back on.
USB connection
This product is a USB device connected to the host via a USB cable.
The USB connector of this product is micro USB as shown below.
- Micro USB compliant (Vbus rating: 0.5A max.)
- Vbus power supply must be provided from the host.
Reception unavailable
Reception available
Command reception
Power supply
The same timing when the power supply
voltage falls under the lower limit of 21.6V
27