![background image](http://html1.mh-extra.com/html/omron/b5l/b5l_user-manual_740786023.webp)
Chapter 2 Installation & Wiring
2-1 Installation
3D TOF Sensor Module B5L User's Manual (No. E596)
How to install
Fix two locations on the bottom using M4 screws.
Screw clamping allowance is 3 to 7mm and tightening torque is 0.91 to 1.37N-m.
Two M4 x 8 screws
Aperture
Design the aperture of the enclosure based on the following dimensions
.
Aperture size of customer's enclosure by thickness [mm]
Thickness
A
B
C
t = 1
28
44
34
t = 2
30
46
36
t = 3
32
48
38
Customer's enclosure
23