Summary of Contents for DATALOG X-PRO 1.0

Page 1: ...Reference Manual 27022019 Rev 6 5 March 2020 DATALOG X PRO 1 0 INTERNET OF THINGS MULTI SENSOR WIRELESS DEVICE User s Manual ...

Page 2: ...ve you can get technical assistance on 1 786 5847439 Monday thru Friday 7 00 a m to 5 00 p m Eastern Standard Time You can also write to info 3sense tech or in Latin America serviciotecnico omicroning co Specialized personnel will discuss your application case Please have the following information available All Configuration Information All Provided Manuals Chip ID and Part list provided with the ...

Page 3: ... in this manual have no safety alert symbol These notices shown below are graded according to the previous definitions Refer to the safety messages listed at the beginning of each section before performing an operation preceded by these symbols Indicates observations that if not followed can cause serious personal injury or damage to the device The information in this tables indicate the risks rel...

Page 4: ... 3 3 1 Main Unit 14 Section 4 Electrical Installation Foreword 16 4 1 Power Requirements 16 4 2 Electrical Ratings 17 4 3 Connection procedure 17 4 3 1 Indoor Use Connection with Power Adapter Supplied 18 4 3 2 Outdoor Use Connect to a Solar Panel Not Provided 18 Section 5 Sensors Selector Guide 21 5 1 Sensor Types 21 5 2 Sensors Connection to Datalog X PRO 23 Section 6 Configuration 25 6 1 Normal...

Page 5: ...37 Appendix A Specifications and Reference Data 40 A 1 Specifications 40 A 1 1 Performance specifications 40 A 1 2 Functional specifications 40 A 1 3 Power supply 41 A 1 4 Communication 41 Appendix B Installation Procedure for a New Sensor 43 Appendix C Sensor Connection Guide 48 C 1 Analog 4 to 20 mA Sensor Interface P N ANA 420mA 48 C 2 Analog 0 10 V Sensor Interface P N ANA 010V 50 C 3 Digital ...

Page 6: ...is prohibited Unauthorized changes to the product are strictly prohibited as they may unintentionally and unpredictably alter performance and safety Unauthorized changes that interfere with the integrity of the enclosure or mounting holes such as making additional perforations compromise the product integrity and safety Equipment ratings and certifications are no longer valid on any products that ...

Page 7: ... performing the operations Information that raises potential safety issues is indicated by a warning symbol Refer to the safety messages listed at the beginning of each section before performing an operation preceded by this symbol 1 1 Product Recycling Disposal Recycling of equipment and packaging should be taken into consideration and disposed in accordance with local and national legislation re...

Page 8: ...arameter setting can be password protected 2 1 Features Datalog X PRO has been thought to easily monitor and deliver data about the evolution of the processes is embedded into As such it relies on a series of functionalities tools and characteristics set to offer the user the desired comfort Among these it is worth to highlight the direct link that devices have with Centriomega Remote Monitoring P...

Page 9: ...as an in built accelerometer 2 Communication module P N X PRO1 0 Sigfox It is responsible for the wireless transmission of data in real time to any platform that allows remote monitoring of the process Communication modules are connected to Remote Monitoring System by default but they could be ordered to correspond to another platform May be Detachable board Sigfox Ready RC2 902 905Mhz RC4 920 923...

Page 10: ... requirements for the sensors that these interfaces receive are listed below Every interface has an in built light indicator to mark whether a sensor is properly operating or not Figure 2 3 Sensor Interface 4 Battery with reference Ultralife UBBP01 3 7 V Lithium Ion Battery Powers the monitoring and transmission system when main supply is off www omicroning co March 2020 10 ...

Page 11: ...y recommended to install the antenna so that its axis is vertical with respect to the ground as this favors the range of the signals transmitted by the device Consider clearing a square area of 25cm at each side in the plane in which Datalog X PRO needs to be installed Mount the system near the center of said clear space so to leave enough margins to comfortably install its peripherals 3 1 Environ...

Page 12: ...enclosure is a standard network ASA squared plastic box Its dimensions are indicated by the following schemes Figure 3 1 Main Enclosure elements Datalog X PRO enclosure elements 1 Top cover 2 Bottom base 3 Blind lids 4 Gasket www omicroning co March 2020 12 ...

Page 13: ... following diagram Figure 3 3 Antenna Dimensions 3 2 3 Protective Valve The user can order Datalog X PRO with a protective vent accessory P N PFM 12 if plans to use the device in harsh environmental conditions such as outdoors The protective valve prevents ingress of a variety of elements such as water dust or other particles while allowing water vapor molecules to diffuse through its microporous ...

Page 14: ...ch the Main Unit will be placed taking into account the distance between the holes previously found 3 Use M3 screws and nuts washers or plastic anchors if needed to fix the device where is required To mount Main Unit on a pole 1 Find the mounting holes covered by the blind lids at opposite borders of the Main Unit enclosure This might be easier after reviewing the previous section 2 Attach the pol...

Page 15: ...alog X PRO operates with sensors and accessories attached it is recommended to leave enough space around the Main Unit to let it hold comfortably its peripherals as shown in the diagram below dimensions in mm Figure 3 6 Recommended free space around Datalog X PRO www omicroning co March 2020 15 ...

Page 16: ...using the Datalog X PRO disconnected from a power source and recharging the device when the battery is almost empty Always observe the following safety instructions Connections must be made only in the complete absence of line voltage If over voltage is expected surge arresters should be used The power adapter provided with the equipment P N GSM06U12 P1J is only for indoor use Use only a safety ce...

Page 17: ...upply could cause damage or unpredictable operation which could result in death or severe personal injury and or property damage To avoid any risk Datalog X PRO manufacturer could be reached to receive further assistance on how to properly connect the equipment Remember that Contact Information is provided at the beginning of this document 4 3 Connection procedure Perform system installation while...

Page 18: ...ams thoroughly before installation Support on electrical wiring handbooks or have your device connected by a qualified licensed electrician All electrical connections must be in accordance with local codes and ordinances If you are unfamiliar with methods of installing electrical wiring secure the services of a qualified electrician 1 Unscrew the jack socket attached to the power cable of Datalog ...

Page 19: ... panel manufacturer for its mounting 5 Loosen the terminal block screws located inside the Solar Panel terminal box 6 Connect DC disconnect switch to mounted Solar Panel Remember to use UL approved cables to link all components and necessary wiring practice to assure electrical safety NOTE It is recommended to install the DATALOG X PRO below the Solar Panel See figure 4 3 since this can prevent ov...

Page 20: ...all the device vertically and at the shadow of the solar panel See figure 4 2 Make sure that the IP67 protection of the the Solar Panel or the Datalog X PRO does not get affected or impaired by the mounting Figure 4 3 Reference Installation of the Datalog X PRO with a Solar Panel www omicroning co March 2020 20 ...

Page 21: ...e different sensors that communicate with the main unit through Sensors Interfaces Their communication methods define the sensor types Sensor types available for Datalog X PRO Digital Analog I 2 C 0 10V DC 1 Wire 0 5V DC Binary dry contact switches 4 20 mA Modbus RTU RS485 Table 5 1 Sensor types available for Datalog X PRO NOTE Sensor of other types can be ordered for more information please conta...

Page 22: ... which require presence sensors smoke sensors or door or window opening sensors Temperature Humidity Pressure Luminosity Presence PIR Digital Signal Smoke Sensor Relay Output Measurement of variables in early warning systems Ultrasound distance measurement 0 10 or 4 20mA Sensor Gas sensors 4 20mA Sensors Measurement of meteorological variables in weather stations and Precision Agriculture Temperat...

Page 23: ...cted Digital Sensors connect directly to Datalog X PRO Humidity Temperature Pressure Luminosity do not need any special procedure for linking To connect Analog Sensors 4 20mA 0 10 V Dry Contacts etc follow the next guidelines 1 Uncover top of the External Terminal Box to gain access to the screw terminals Figure 5 1 Uncovered External Terminal Box 2 Remove approximately 1 in 2 5 mm of the mantle o...

Page 24: ...n the thickness of the cable select the correct rubber bushing of 5 mm or 7 4 mm both are supplied 5 Unscrew the necessary terminals and then insert the uncovered wires in their corresponding lines To facilitate this task each sensor end should be tinned or connected to a crimp terminal To know in which order each end must be connected refer to Sensors connection Guide in Appendix C www omicroning...

Page 25: ... show that the device is reading sensors configuring its Communications Module sending data or accepting a command Refer to next table to understand the proper Datalog X PRO LED indicator operation Table 6 1 Front Panel LED indicator Led Operation Function Short blue flashes Sensor Reading Short green flashes Config Comm module 3 green one second flashes Sending data to Internet Red flash Configur...

Page 26: ...le in Normal Operating Mode as long as a magnet is placed near the Main Unit as described before the LED Indicator will shine red Depending on the number of times the magnet is briefly brought close to the Main Unit users can reach one of the alternative states indicated below www omicroning co March 2020 26 ...

Page 27: ...ted to each sensor to be used Service Mode allows this setting This mode can be accessed after briefly joining a magnet near the main unit 4 times After approaching the magnet as indicated the visual indicator will light violet 4 times to indicate that the device is about to enter the Service Mode Once the device has entered this mode the LED indicator will flash red every second www omicroning co...

Page 28: ...orms where the device administrator can specify parameters relative to the wireless communication networks to which the device being configured will be connected To quit this mode briefly place a magnet near the Main Unit 1 time 6 2 2 Send Data The configured publication time for each sensor will naturally limit the data transmissions executed by Datalog X PRO However the device may be forced to s...

Page 29: ...ne coverage USA Mexico Brazil Sigfox Zone 2 Latin America and Australia Sigfox Zone 4 If the LED Indicator flashes 4 times the device is being set to work in zone 4 of the network on the other hand if such LED lights twice it is to show that the device will be configured to operate in zone 2 of the network Remember that LED Indicator will flash green only to show that the device is configuring its...

Page 30: ... Fi page enter the credentials SSID and password of the network to which you want Datalog X PRO to connect then press Save If the entered credentials are invalid the next page will appear Figure 6 5 Not Proper Wi Fi Configuration Otherwise you will see www omicroning co March 2020 30 ...

Page 31: ...peration select the correct Sigfox module Configuration in the Datalog X PRO see section 6 2 4 depending of the Sigfox Zone coverage USA Mexico Brazil Sigfox Zone 2 Latin America and Australia Sigfox Zone 4 6 5 Check Other Settings If you wish to see the factory ID of the Communications Module that is being configured its firmware version its MAC or its latest assigned dynamic IP follow the next s...

Page 32: ...Figure 6 7 Other Information page www omicroning co March 2020 32 ...

Page 33: ...ls Add comments to alarm records Set alarm limits among other custom settings like sensors names Set alarm events such as e mail or SMS notifications 7 1 Access to Centriomega Remote Monitoring Platform Using the credentials provided by the manufacturer device s user can log in at iot omicroning co Figure 7 1 Access to Remote Monitoring Platform The platform uses some basic elements to organize th...

Page 34: ... to the platform and panels to display Alarms or Events that have recently occurred To review a Dashboard initially follow what is indicated in 7 1 to access the platform Inside the platform users can find a link to the section that includes all the Dashboards available to their accounts There they can select the Dashboard of their interest Figure 7 2 Dashboard Selection After selecting a particul...

Page 35: ...ough a particular network to the platform Thus each Device visible to an account receives the data of the physical equipment acquired by the administrator of said account The data received by a device is stored and organized in multiple variables To review a specific Device initially follow what is indicated in 7 1 to access the platform Inside the platform users can find a link to the section tha...

Page 36: ...and Variables Reviewing the Variables of a certain Device allows checking the update status and presence of each Variable If is suspected that one variable is not being updated properly after entering the Device panel that should include it its last activity period could be reviewed Figure 7 5 Reviewing the Variables of a Device www omicroning co March 2020 36 ...

Page 37: ...ssages via email SMS Telegram or Webhooks Violated conditions which may have involved sending messages to users can be reviewed in a Dashboard associated with your account in whose name the suffix Alarms is included To review an Event initially follow what is indicated in 7 1 to access the platform Inside the platform users can find a link to the section that includes all Events available to their...

Page 38: ...activity of an Event its log of updates or the times in which one of its conditions have been violated the user can press the Log icon associated to any Event to see a table like the following Figure 7 7 Events Historical www omicroning co March 2020 38 ...

Page 39: ...and look for the Dashboard whose name contains the suffix Alarms This Dashboard will contain a table like the following Figure 7 7 Events Dashboard To learn how to modify the configuration of an Event refer to the manufacturer s guide provided for it www omicroning co March 2020 39 ...

Page 40: ...cation of different sensors available to connect to Datalog X PRO A 1 2 Functional specifications General Features Ports for three sensors Wi Fi Sigfox wireless transmission modules Rechargeable Li Ion Battery Visualization Web App interface for visualization of Current sensed measures Alarm limits configuration among other parameters Graphic record of each variable for up to 2 years Alarms Remote...

Page 41: ...2 P1J Mean Well Nominal Input 110 to 220 VAC 10 50 60HZ 12VDC 500Ma Input 85 264VAC 47 63Hz 0 18A 100VAC Max 30A 230VAC Rated Output 12V 5 0 0 0 5A Power Rating Max 6W 12VDC UL Recognized Component IEC60950 1 ANSI AAMI ES60601 1 11 approved Compliance to FCC part 15 Class B Online Certification Directory entry QQHM2 E227340 A 1 4 Communication A 1 4 1 Sigfox Module Datalog X PRO Sigfox Certificati...

Page 42: ...A 1 4 2 Wi Fi Module Radio Module ESP12F AiThinker WiFi Module 2 4 GHz FCC ID 2ADUIESP 12 www omicroning co March 2020 42 ...

Page 43: ... prohibited It could cause damage or unpredictable operation which could result in death or severe personal injury and or property damage Always observe the following safety instructions for connect the sensor interfaces Connections should be made only by trained personnel authorized by the manufacturer Connections must be made only in the complete absence of line or battery voltage Remember that ...

Page 44: ...followed 1 Uncover Main Unit s top to gain access to the base board and install the Sensor Interface in a free port Figure B 1 Uncovered Datalog X PRO with the correct position of each Sensor Interface and Communication Sigfox Module 2 Remove approximately 1 in 2 5 mm of the cable mantle and strip approximately 0 2 in 5 mm off the edge of each conductor Figure B 2 Sensor Wires Cut ted www omicroni...

Page 45: ... ends into the Main Unit It is recommended to let such sensor ends to pass under the Interface board as this would facilitate its connection 6 Unscrew the necessary ports of the chosen Interface screw terminal and then insert the uncovered wires in their corresponding lines To facilitate this task each sensor end should be tinned To know in which order each end must be connected to said screw term...

Page 46: ...d be connected to sensor s VCC 3 3V GND_S should be connected to sensor s GND SDA It must be connected to the SDA channel of a digital sensor for example of type I2C This pin could be configured as well as an I O port in the firmware SCL It must be connected to the SCL channel of a digital sensor for example of type I2C This pin could be configured as well as an I O port in the firmware www omicro...

Page 47: ... analog input channel It can be used to measure currents from 4 to 20mA or voltages from 0 to 10V DC for voltage measurement a 450 ohm in series resistor should be connected It is mandatory to connect a series resistor of 450 Ω 1 Watt for 0 to 10V DC or 0 to 5VDC voltage measurement To connect any peripheral demand help from the manufacturer Remember that Contact Information is provided at the beg...

Page 48: ...A Maximum Input voltage of a channel 1 1 VDC C 1 2 Specifications PARAMETER Operational Range Temperature 41 F 104 F 5 C to 40 C Relative humidity 25 75 Accuracy 0 1 mA at reference conditions Resolution 0 01 mA Digital Conversion Range 0 to 2200 Output 0 0 mA Output 2200 22 mA Exceeding the ranges defined for any Interface channel could cause damage or unpredictable operation which could result i...

Page 49: ...C 1 3 Connection Diagram Figure C1 1 4 20mA Sensor Interface Connection Figure C1 2 External Sensor Connection through Terminal Box www omicroning co March 2020 49 ...

Page 50: ...PARAMETER Ratings Supply Voltage from Datalog X PRO 3 3 V DC Input Voltage Range 0 11 V DC Maximum Input voltage of a Channel 11 V DC using a 450 Ohm Series Resistor C 2 2 Specification PARAMETER Operational Range Temperature 41 F 104 F 5 C to 40 C Relative humidity 25 75 Accuracy 0 25 V at reference conditions Resolution 0 01V Digital Conversion Range 0 to 1100 Output 0 0 VDC Output 1100 11 VDC C...

Page 51: ...peration which could result in death or severe personal injury and or property damage To avoid any risk Datalog X PRO manufacturer should be reached to receive further assistance on how to properly connect peripherals Remember that Contact Information is provided at the beginning of this document www omicroning co March 2020 51 ...

Page 52: ...cted state changes C 3 1 D C Electrical Characteristics PARAMETER Ratings Supply Voltage from Datalog X PRO 3 3 VDC Supply Output Current to a Dry Contact 0 33mA Maximum Output Voltage 3 3VDC C 3 2 Specifications PARAMETER Operational Range Temperature 41 F 104 F 5 C to 40 C Relative humidity 25 75 Resolution 1 bit Digital Conversion Range 0 or 1 C 3 3 Connection Diagram Figure C3 1 Digital Binary...

Page 53: ...nel could cause damage or unpredictable operation which could result in death or severe personal injury and or property damage To avoid any risk Datalog X PRO manufacturer should be reached to receive further assistance on how to properly connect peripherals Remember that Contact Information is provided at the beginning of this document www omicroning co March 2020 53 ...

Page 54: ...to the Internet for subsequent analysis C 4 1 D C Electrical Characteristics PARAMETER Ratings Supply Voltage from Datalog X PRO 3 3 VDC Modbus Communication Protocol RS 485 RTU C 4 2 Specifications PARAMETER Operational Range Temperature 41 F 104 F 5 C to 40 C Relative humidity 25 75 Digital Conversion Range Programmable for Read Modbus Registers NOTE For More Information About Modbus Interface C...

Page 55: ...ould cause damage or unpredictable operation which could result in death or severe personal injury and or property damage To avoid any risk Datalog X PRO manufacturer should be reached to receive further assistance on how to properly connect peripherals Remember that Contact Information is provided at the beginning of this document www omicroning co March 2020 55 ...

Page 56: ...for subsequent analysis C 5 1 D C Electrical Characteristics PARAMETER Ratings Supply Voltage from Datalog X PRO 3 3 VDC Maximum Supply Current from Datalog X PRO 10mA Maximum Input Output voltage for an I2C Signal 3 3 V C 5 2 Specifications Of Interface PARAMETER Operational Range Temperature 41 F 104 F 5 C to 40 C Relative humidity 25 75 Accuracy Resolution Depends of the sensor selected Digital...

Page 57: ... H 300 to 1100hPa DIG LUX1 Digital Luminosity Sensor Resolution 10 luxes Accuracy 10 luxes Range 0 to 120000 Luxes Exceeding the ranges defined for any Interface channel could cause damage or unpredictable operation which could result in death or severe personal injury and or property damage To avoid any risk Datalog X PRO manufacturer should be reached to receive further assistance on how to prop...

Page 58: ...ETER Ratings Supply Voltage from Datalog X PRO 3 3 VDC Supply Current from Datalog X PRO 0 2mA Maximum Input voltage of Digital Signal 3 3 V C 6 2 Specifications PARAMETER Operational Range Temperature for Interface 77 F 9 F 25 C 5 C Relative humidity for Interface 25 75 Temperature range for Sensor Probe 40 to 80 C Accuracy 0 5 C Digital Conversion Range Two Bytes number in two s complement forma...

Page 59: ...ld result in death or severe personal injury and or property damage To avoid any risk Datalog X PRO manufacturer should be reached to receive further assistance on how to properly connect peripherals Remember that Contact Information is provided at the beginning of this document www omicroning co March 2020 59 ...

Page 60: ...www omicroning co March 2020 60 ...

Page 61: ...29 USA info 3sense tech Phone 1 786 584 7439 Latin America Regional Office Omicron Ingenieria SAS Address Cra 46 38 62 Off 502 Medellin Colombia Phone 57 4 2328381 WhatsApp 57 317 4365062 comercial omicroning co www omicroning co 2018 Omicron Ingenieria SAS All rights reserved www omicroning co March 2020 61 ...