After approaching the magnet as indicated, the visual indicator will light violet 8 times to indicate
that the device is about to Sleep/Off. Remember that LED Indicator will flash green only to show
that the device is configuring its Communications Module, or sending data.
To quit this mode, briefly place a magnet near the Main Unit 1 time.
6.2.4 Change Sigfox Zone
Datalog X-PRO 1.0 is able to transmit in zones 2 or 4 of Sigfox network. Therefore, if the user
wants to configure the zone in which the device operates, he should
briefly join a magnet near
the Main Unit 10 times.
After this, the device will respond with its LED Indicator.
NOTE:
For proper operation select the correct Sigfox module in the
Datalog X-PRO
depending of the
Sigfox Zone coverage:
USA, Mexico, Brazil:
Sigfox Zone 2.
Latin America and Australia:
Sigfox Zone 4.
If the LED Indicator flashes 4 times, the device is being set to work in zone 4 of the network; on the
other hand, if such LED lights twice, it is to show that the device will be configured to operate in
zone 2 of the network.
Remember that LED Indicator will flash green only to show that the device is configuring its
Communications Module, or sending data.
6.3 Connect Datalog X-PRO to a Wi-Fi® network
To set the SSID of the network to which the device will be connected, and its password, proceed
as follows:
1. On the Home Page (as seen in 6.2.1), press the Configure Wi-Fi® button to be directed to
a page where you can see a scan of Wi-Fi® networks detected by the device as available, 2
input fields, and two buttons (Save and Scan).
The page that loads after selecting Configure Wi-Fi®, on Home Page, is presented in the
following image:
www.omicroning.co March 2020
29