background image

Page - 6

arm/lock

Pressing and releasing  the “arm/lock” button arms the security system
and  locks the doors.

Pressing and holding this button for three seconds will first arm, and then
activate the Panic feature, locking the doors.

Pressing the “arm/lock” and “disarm/unlock” buttons together activates
the remote starting feature of the MAX-EDP.

disarm/unlock

Pressing and releasing the “disarm/unlock” button disarms the system
and unlocks the doors unless the alarm is triggered, in which case it will
disarm the activated alarm, but not unlock the doors unless the button
is pressed again.

Pressing and holding this button for three seconds will first disarm, and
then activate the Panic feature, unlocking the doors.

The unlock operation may be optionally configured during the system’s
installation so that pressing this button once disarms the system and
unlocks only the driver's door, and pressing a second time unlocks all
of the doors.

The

 Transmitter

panic

” button

OPTION

” button

arm/lock

     button

disarm/unlock

button

Transmitter part numbers:
146-17B
 black case, gray buttons
146-17G translucent case, glow buttons

Transmitter battery replacement:

Remove the small screw from the lower

back case, and separate the transmitter

case halves. Replace the CR2032 coin-

type battery and reassemble the transmitter.

Page - 39

The first setting (programmed by the “arm/lock” button) has the system
produce both the lock and unlock outputs as .8 second in duration.  This
is the most common form needed, which interfaces most vehicles.

The second setting (programmed by the “disarm/unlock” button)
changes the lock and unlock outputs to be a longer 3 second pulse
output.  This is for certain vehicles which require a longer output pulse
from the system’s control unit; typically cars having vacuum pump
systems, although the longer setting is also more suitable in some
newer vehicles.

Some newer vehicles require a double pulse output to remotely unlock
the doors and/or to disarm a factory-equipped security system, which is
what the Double Pulse Unlock setting provides (it is programmed by the

OPTION

 button ).  The lock output pulse, in this setting, is .8 second.

The Total Closure Lock Output (programmed by the “panic” button) may
be used with vehicles which are originally equipped with the total-
closure feature.  Typically, a total closure feature is when locking the
vehicle’s doors if the key in the door is held to “lock” for a period of time
the vehicle will close all windows and the sunroof, in addition to locking
the doors.  Selecting this feature setting changes the system’s door lock
output pulse from a .8 second to as long as a 28 second duration output.
The unlock output is 3 seconds in this setting.

Note: When this feature is turned on, during the 28 second period after
arming the system, the lock output can be stopped on demand by press-
ing the “arm/lock” or “disarm/unlock” button.  Only the output will stop-
pressing either button again will normally operate the system, and at
any time after the 28 second lock output period ends.

If either of the programmable relays are set for lock or unlock operation
(the next two Installer Programmable Features), the settings if this feature
will operate the programmable relays accordingly, in addition to the pri-
mary system doorlocking outputs.

Feature #2   Light Relay Functions

Factory Default Setting

Dome Light Output
(press “arm/lock” button to program)

Options:
Door Lock

(press “disarm/unlock” button to program)

Ignition Output

(press 

OPTION

 button  to program)

Accessory Output

(press red 

panic

 button  to program)

The Omega MAX-EDP has two built-in relays, which can be programmed
to perform several different functions.  The primary function of this relay, is
to operate the vehicle’s dome, or interior lighting as part of the system’s
operations.  Optionally, if desired or needed, this relay can be programmed

Summary of Contents for MAX-EDP

Page 1: ...God This warranty limits the Company s liability to the repair or replacement of theproduct TheCompanyshallnotberesponsibleforremovaland orreinstallation charges damage to or theft of the vehicle or...

Page 2: ...O 4 Starter Interrupt Functions Alarm only L Off U Automatic O Alarm AntiGrind p 5 Ignition Activated Override OFF U ON L 6 Doors Lock With Ignition On ON L OFF U 7 Doors Unlock With Ignition Off ON...

Page 3: ...engine has started running Feature 10 Gasoline Or Diesel Engine Factory Default Setting Gasoline press arm lock button to program Option Diesel press disarm unlock button to program This feature chang...

Page 4: ...hich keeps the engine running after removing the ignition key After exiting the user must then arm the system locking the vehicle doors by pressing the arm lock button Only after this is done will the...

Page 5: ...nsmission equipped vehicles via a setup procedure which must be followed upon exiting the vehicle When this feature is turned on the operator must set the parking brake and then Feature 4 Turbo Timer...

Page 6: ...s also more suitable in some newer vehicles Some newer vehicles require a double pulse output to remotely unlock the doors and or to disarm a factory equipped security system which is what the Double...

Page 7: ...e Installer Programmable Features are accessed as the second level of features programming which is pressing the Valet Switch 10 times instead of 5 times when entering Programming Mode page 27 Caution...

Page 8: ...n the red color The system s reaction The parking and interior lights will flash once the siren will chirp once and the Status Light will begin to flash red confirming that the system is armed In addi...

Page 9: ...Last Door Arming process stops and will reset to start over when the point of entry is again closed All protected entries must be closed to initiate the Last Door Arming sequence To temporarily preve...

Page 10: ...ded Last Door Arming offers a high level of security since you do not have to remember to arm the security system every time you leave the vehicle and using it may entitle you to an insurance discount...

Page 11: ...cations and Zone Violation code will remain this way until the ignition key is turned on Page 34 Feature 11 Alarm Duration Factory Default Setting 30 Seconds press arm lock button to program Options 6...

Page 12: ...hin 5 seconds press and release the Valet Switch one time The system will disarm Step 2 Using the ignition key turn the vehicle s ignition switch on The number of Valet Switch presses which are requir...

Page 13: ...Factory Default Setting Off press disarm unlock button to program Option On press arm lock button to program This feature allows an activated system to be overridden and disarmed by simply turning th...

Page 14: ...it on demand before it times out again press and releasetogetherthetransmitter s arm lock and disarm unlock buttons The system will stop the engine and extinguish the parking lights This feature turn...

Page 15: ...mega MAX EDP is installed into a manual transmission vehicle Installer Program mable Feature 5 must be turned on Then whenever remote starting will be desired at a later time the following procedure m...

Page 16: ...he engine running normally from the ignition switch have the gear selector in park and your foot off of the brake pedal Press the Valet Switch twice the parking lights will flash once and the siren ch...

Page 17: ...he same number of times as the desired feature s number The siren will chirp and the Status Indicator Light will flash as many times as the Valet Switch was pressed to indicate the feature number whic...

Page 18: ...ressing the disarm unlock and red panic buttons will activate the 5th channel Or if desired the transmitter panic button can be programmed by User Programming Feature 21 to operate any of these channe...

Page 19: ...r optional controllers which are to operate the system at hand Turn the ignition on If the Unauthorized Transmitter Alert feature is on programming a transmitter or optional controller to the system w...

Page 20: ...er AlertTM UTA is a protection feature which may be turned on by the user see the next section How to Program Transmitters Whenthisprotectionfeatureisutilized wheneveratransmitter or optional 2 way co...

Page 21: ...jackingprotection features whose operation may be selectively activated by the ignition by an open door or by the transmitter All three are programmable and must be turned on to operate Once activated...

Page 22: ...ogrammed 6 2 Red Flashes pause 2 transmitters are programmed 9 2 Red Flashes Pause System was triggered by open hood or trunk 10 3 Red Flashes Pause System was triggered by an open door 21 Slowly Alte...