Emergency Override is custom-programmable!  This is the SecureCode
feature, which is described on page 21.  The above Emergency Override
instructions reflect the “as received from the factory” default setting.

Page - 13

Should you feel threatened, or the need to attract attention, you can

activate your system's remote “Panic” feature  at any time by pressing and
holding for 3 seconds the transmitter’s  “arm/lock”, the “disarm/unlock”, or
the “panic” button.  Your system will respond by sounding the siren and
flashing the parking lights for the normal activated alarm period of 30
seconds.
Additionally, the MAX-EDP system features an unique “enhanced” remote
Panic operation, regarding additional operations during Panic, and in
association with the transmitter button used in it’s activation or deactivation:

Remote Panic Feature

To disengage remote Panic, simply press and release any one of the same
three transmitter buttons, or, allow it automatically stop after 30 seconds.

Activating Panic with the red “panic” button will not affect the system’s
armed or disarmed status; the doors locked or unlock condition; nor will
it affect the starter disable circuit.

Activating it with the “disarm/unlock” button will unlock the doors,
disarm the system and does not engage the starter interrupt.

Activating Panic with the “arm/lock” button will lock the doors, arm the
system and engage the starter interrupt.

Deactivating Panic with the “arm/lock” button will stop Panic, and leave
the

system armed with the starter interrupt engaged, and the doors

locked.

Deactivating it with the “disarm/unlock” button will stop Panic, and
leave the system disarmed with the starter interrupt disengaged, and
the doors unlocked.

If the system is allowed reset itself from remote Panic, it will enter the
armed state, locking the doors and engaging the starter interrupt,
regardless of which of the three buttons was used to activate it.

Deactivating Panic with the “panic” button will stop Panic, and leave the
system in the same state it was in at the moment Panic started, without
locking or unlocking the doors.

Feature #5   Ignition Activated Override

Factory Default Setting

Off      (press “disarm/unlock” button to program)

Option:

On      (press “arm/lock” button to program)

This feature allows an activated system to be overridden and disarmed by
simply turning the ignition switch on within 10 seconds of the system’s
activation.  After 10 seconds, the Emergency Override must be performed
or  the transmitter’s “disarm/unlock” button can be used to disarm the
system.

Feature #6   Doors Lock With Ignition On

Factory Default Setting

On      (press “arm/lock” button to program)

Option:

Off      (press “disarm/unlock” button to program)

This feature configures the system to automatically lock the vehicle’s doors
every time that the ignition switch is turned on.  An exception to this would
be if feature #8 is turned on, and a door being open when the ignition switch
is turned on.  The following feature #7 controls the automatic unlocking
operations, and feature #8 provides for an override of this automatic locking
if a door is open when the ignition is turned on.

Feature #7   Doors Unlock With Ignition Off

Factory Default Setting

On (all doors will unlock)*
(press red 

panic

 button  to program)

Options:
Off

(press “arm/lock” button to program)

Driver’s Door Only*

       (press “disarm/unlock” button  to program)

All Doors Except Driver’s Door*

(press 

OPTION

 button  to program)

Similar to the previous locking feature, except this feature controls the
unlock operations when the ignition is turned off, and it has more options
because of the MAX-EDP’s multiple unlocking outputs.

*Multiple unlock outputs offer the capability of unlocking only the driver’s

door when the system is disarmed (Driver Door Priority Unlocking), and
then the option of unlocking all doors with a second press of the  “disarm/
unlock
” button.   The driver’s door unlocking differently from the other
doors must be configured when the system is installed!

If the system is installed without the Driver’s Door Priority Unlocking

interface, this feature unlocks all of the doors when the ignition switch is
turned off.
If Driver’s Door Priority Unlocking is installed, this feature can control only
the driver’s door unlocking when the ignition is turned, all doors unlocking,
or all doors except the driver’s.  The following feature provides for an
override of this automatic unlocking if a door is open when the ignition is
turned off.

Page - 32

Summary of Contents for MAX-EDP

Page 1: ...God This warranty limits the Company s liability to the repair or replacement of theproduct TheCompanyshallnotberesponsibleforremovaland orreinstallation charges damage to or theft of the vehicle or...

Page 2: ...O 4 Starter Interrupt Functions Alarm only L Off U Automatic O Alarm AntiGrind p 5 Ignition Activated Override OFF U ON L 6 Doors Lock With Ignition On ON L OFF U 7 Doors Unlock With Ignition Off ON...

Page 3: ...engine has started running Feature 10 Gasoline Or Diesel Engine Factory Default Setting Gasoline press arm lock button to program Option Diesel press disarm unlock button to program This feature chang...

Page 4: ...hich keeps the engine running after removing the ignition key After exiting the user must then arm the system locking the vehicle doors by pressing the arm lock button Only after this is done will the...

Page 5: ...nsmission equipped vehicles via a setup procedure which must be followed upon exiting the vehicle When this feature is turned on the operator must set the parking brake and then Feature 4 Turbo Timer...

Page 6: ...s also more suitable in some newer vehicles Some newer vehicles require a double pulse output to remotely unlock the doors and or to disarm a factory equipped security system which is what the Double...

Page 7: ...e Installer Programmable Features are accessed as the second level of features programming which is pressing the Valet Switch 10 times instead of 5 times when entering Programming Mode page 27 Caution...

Page 8: ...n the red color The system s reaction The parking and interior lights will flash once the siren will chirp once and the Status Light will begin to flash red confirming that the system is armed In addi...

Page 9: ...Last Door Arming process stops and will reset to start over when the point of entry is again closed All protected entries must be closed to initiate the Last Door Arming sequence To temporarily preve...

Page 10: ...ded Last Door Arming offers a high level of security since you do not have to remember to arm the security system every time you leave the vehicle and using it may entitle you to an insurance discount...

Page 11: ...cations and Zone Violation code will remain this way until the ignition key is turned on Page 34 Feature 11 Alarm Duration Factory Default Setting 30 Seconds press arm lock button to program Options 6...

Page 12: ...hin 5 seconds press and release the Valet Switch one time The system will disarm Step 2 Using the ignition key turn the vehicle s ignition switch on The number of Valet Switch presses which are requir...

Page 13: ...Factory Default Setting Off press disarm unlock button to program Option On press arm lock button to program This feature allows an activated system to be overridden and disarmed by simply turning th...

Page 14: ...it on demand before it times out again press and releasetogetherthetransmitter s arm lock and disarm unlock buttons The system will stop the engine and extinguish the parking lights This feature turn...

Page 15: ...mega MAX EDP is installed into a manual transmission vehicle Installer Program mable Feature 5 must be turned on Then whenever remote starting will be desired at a later time the following procedure m...

Page 16: ...he engine running normally from the ignition switch have the gear selector in park and your foot off of the brake pedal Press the Valet Switch twice the parking lights will flash once and the siren ch...

Page 17: ...he same number of times as the desired feature s number The siren will chirp and the Status Indicator Light will flash as many times as the Valet Switch was pressed to indicate the feature number whic...

Page 18: ...ressing the disarm unlock and red panic buttons will activate the 5th channel Or if desired the transmitter panic button can be programmed by User Programming Feature 21 to operate any of these channe...

Page 19: ...r optional controllers which are to operate the system at hand Turn the ignition on If the Unauthorized Transmitter Alert feature is on programming a transmitter or optional controller to the system w...

Page 20: ...er AlertTM UTA is a protection feature which may be turned on by the user see the next section How to Program Transmitters Whenthisprotectionfeatureisutilized wheneveratransmitter or optional 2 way co...

Page 21: ...jackingprotection features whose operation may be selectively activated by the ignition by an open door or by the transmitter All three are programmable and must be turned on to operate Once activated...

Page 22: ...ogrammed 6 2 Red Flashes pause 2 transmitters are programmed 9 2 Red Flashes Pause System was triggered by open hood or trunk 10 3 Red Flashes Pause System was triggered by an open door 21 Slowly Alte...