background image

This device complies with FCC Rules part 15. Operation is subject to the
following two conditions, (1) This device may not cause harmful inter-
ference and, (2) This device must accept any interference that may be
received, including interference that may cause undesired operation.

The manufacturer is not responsible for any radio or TV interference
caused by unauthorized modifications to this equipment. Such modifica-
tions could void the user's authority to operate the equipment.

One or more of these patents may apply to this product:

#5,612,669  #5,654,688  #5,663,704  #5,729,191  #5,818,329  #5,612,578  #5,739,747

#382,558  #385,878  #5,750,942  #5,739,748  #5,719,551  #406,107  #701,285

#5,973,592  #5,982,277  #5,986,571  #6,011,460  #6,037,859  #6,049,268  #6,130,605

#6,130,606  #6,140,938  #6,140,939  #6,150,926  #6,144,315 #6,184,780 #6,188,326

#6,243,004  #6,249,216  #6,275,147  #6,297,731  #6,320,514  #6,320,498

Foreign Patent #199700312  #EP0817734B1 #98906445.6 #2,320,248 #701,285

Omega Research and Development, Inc.

www.caralarm.com

Page - 2

Coin batteries used in the transmitter which is used to operate this
security system may contain Perchlorate Material - special handling
may apply.  See www.dtsc.ca.gov/hazardouswaste/perchlorate

Page - 43

Complete Programmable Features Matrix

USER Features

Ignition on, off, then press Valet Switch 5 times (RED Status Light).

   #

 Feature

  Default Setting             Option

     2nd Option

     3rd Option

   1

SecureCode

 1 & 0                     2 stages, of up to 9 presses each (total of 99 possible combinations)

   2

Last Door Arming

OFF (L)

ON w/o doorlock (U) ON w/ doorlock (O)

   3

Automatic Rearming

OFF (L)

ON w/o doorlock (U) ON w/ doorlock (O)

   4

Starter Interrupt Functions

Alarm only (L)

Off (U)

Automatic (O)

Alarm+AntiGrind (p)

   5

Ignition Activated Override

OFF (U)

ON (L)

   6

Doors Lock With Ignition On

ON  (L)

OFF (U)

   7

Doors Unlock With Ignition Off ON  (p)

OFF (L)

o/p 1 only (O)

o/p 2 only (O)

   8

Open Door Bypass to above

ON  (L)

OFF (U)

   9

Confirmation Chirps

ON (L)

OFF (U)

exc. Valet (O)

Valet only (p)

 10 Confirmation Chirp Volume

Medium Loud  (O) Low (L)

Med Lo (U)

Loud (p)

 11

Activated Alarm Cycle

 30 Seconds (L)

60 Sec. (U)

90 Sec. (O)

120 Sec. (p)

 12 Lights On Upon Disarm

ON  (L)

OFF (U)

 13 Disarm Upon Trunk Release

ON  (L)

OFF (U)

 14 Arming Delay

3 Seconds (L)

15 Seconds (U)

30 Seconds (O)

45 Seconds (p)

 15 Steady Siren / Pulsed Horn

Steady Siren (L)

Pulsed Horn Lo (U)

Pulsed Med. (O)

Pulsed Hi (p)

 16 Alarm Functions Bypass

OFF (U)

ON (L)

 17 Ignition Anti-Carjacking

OFF (U)

ON (L)

 18 Door Anti-Carjacking

OFF (U)

ON (L)

 19 Remote Anti-Carjacking

OFF (U)

ON (L)

 20 Open Door Warning at Arm

OFF (U)

ON (L)

 21 Red “panic” Button Operation

Panic (L)

3rd Chan. (U)

4th Chan. (O)

5th Chan. (p)

 22 Remote Start Run Time

10 Min. (U)

5 min. (L)

15 min. (O)

20 min. (p)

 23 Steady/Flash Lights Rem. Start Steady (L)

Flashing (U)

INSTALLER  Features

Ignition on, off, then press Valet Switch 10 times (GREEN Status Light).

  1

Doorlock Functions

.8 second (L)

3 Seconds (U)

Double Unlock (O) Total Closure (p)

  2

Light Relay Functions

Dome Light (L)

Lock (U)

Ignition (O)

Accessory (p)

  3

Horn Relay Functions

Horn, med. (L)

Unlock (U)

Ignition (O)

Accessory (p)

  4

Turbo Timer

OFF (U)

ON (L)

  5

Manual Trans. Remote Start

OFF (U)

ON (L)

  6

“Tach Wire” or “Tachless “

Tachless (L)

Tach (U)

  7

Ext. Starter Cranking Time

.7 (minimum) ( L) 1.25 (U)

1.75 (O)

2.5 (maximum) (p)

  8

Remote Start Relay

Ignition (L)

Accessory (U)

Starter (O)

  9

Arm/Disarm or Add. Chan.

Arm/Disarm (L)

Arm/Ch. 5 (U)

Ch. 4 / Disarm (O)

Ch. 4 / Ch. 5 (p)

 10 Gasoline or Diesel Engine

Gasoline (L)

Diesel (U)

(L) = “arm/lock”      (U) = “disarm/unlock”

(O) = “OPTION”      (p) = red “panic”

Summary of Contents for MAX-EDP

Page 1: ...God This warranty limits the Company s liability to the repair or replacement of theproduct TheCompanyshallnotberesponsibleforremovaland orreinstallation charges damage to or theft of the vehicle or...

Page 2: ...O 4 Starter Interrupt Functions Alarm only L Off U Automatic O Alarm AntiGrind p 5 Ignition Activated Override OFF U ON L 6 Doors Lock With Ignition On ON L OFF U 7 Doors Unlock With Ignition Off ON...

Page 3: ...engine has started running Feature 10 Gasoline Or Diesel Engine Factory Default Setting Gasoline press arm lock button to program Option Diesel press disarm unlock button to program This feature chang...

Page 4: ...hich keeps the engine running after removing the ignition key After exiting the user must then arm the system locking the vehicle doors by pressing the arm lock button Only after this is done will the...

Page 5: ...nsmission equipped vehicles via a setup procedure which must be followed upon exiting the vehicle When this feature is turned on the operator must set the parking brake and then Feature 4 Turbo Timer...

Page 6: ...s also more suitable in some newer vehicles Some newer vehicles require a double pulse output to remotely unlock the doors and or to disarm a factory equipped security system which is what the Double...

Page 7: ...e Installer Programmable Features are accessed as the second level of features programming which is pressing the Valet Switch 10 times instead of 5 times when entering Programming Mode page 27 Caution...

Page 8: ...n the red color The system s reaction The parking and interior lights will flash once the siren will chirp once and the Status Light will begin to flash red confirming that the system is armed In addi...

Page 9: ...Last Door Arming process stops and will reset to start over when the point of entry is again closed All protected entries must be closed to initiate the Last Door Arming sequence To temporarily preve...

Page 10: ...ded Last Door Arming offers a high level of security since you do not have to remember to arm the security system every time you leave the vehicle and using it may entitle you to an insurance discount...

Page 11: ...cations and Zone Violation code will remain this way until the ignition key is turned on Page 34 Feature 11 Alarm Duration Factory Default Setting 30 Seconds press arm lock button to program Options 6...

Page 12: ...hin 5 seconds press and release the Valet Switch one time The system will disarm Step 2 Using the ignition key turn the vehicle s ignition switch on The number of Valet Switch presses which are requir...

Page 13: ...Factory Default Setting Off press disarm unlock button to program Option On press arm lock button to program This feature allows an activated system to be overridden and disarmed by simply turning th...

Page 14: ...it on demand before it times out again press and releasetogetherthetransmitter s arm lock and disarm unlock buttons The system will stop the engine and extinguish the parking lights This feature turn...

Page 15: ...mega MAX EDP is installed into a manual transmission vehicle Installer Program mable Feature 5 must be turned on Then whenever remote starting will be desired at a later time the following procedure m...

Page 16: ...he engine running normally from the ignition switch have the gear selector in park and your foot off of the brake pedal Press the Valet Switch twice the parking lights will flash once and the siren ch...

Page 17: ...he same number of times as the desired feature s number The siren will chirp and the Status Indicator Light will flash as many times as the Valet Switch was pressed to indicate the feature number whic...

Page 18: ...ressing the disarm unlock and red panic buttons will activate the 5th channel Or if desired the transmitter panic button can be programmed by User Programming Feature 21 to operate any of these channe...

Page 19: ...r optional controllers which are to operate the system at hand Turn the ignition on If the Unauthorized Transmitter Alert feature is on programming a transmitter or optional controller to the system w...

Page 20: ...er AlertTM UTA is a protection feature which may be turned on by the user see the next section How to Program Transmitters Whenthisprotectionfeatureisutilized wheneveratransmitter or optional 2 way co...

Page 21: ...jackingprotection features whose operation may be selectively activated by the ignition by an open door or by the transmitter All three are programmable and must be turned on to operate Once activated...

Page 22: ...ogrammed 6 2 Red Flashes pause 2 transmitters are programmed 9 2 Red Flashes Pause System was triggered by open hood or trunk 10 3 Red Flashes Pause System was triggered by an open door 21 Slowly Alte...