background image

Other Transmitter Operations

The 2nd channel output, which is operated by pressing and holding the

transmitter 

OPTION

 button for 1 second, is designed specifically to

operate your vehicle’s 

electric power trunk release.  Your vehicle will

respond by releasing the trunk lid or rear hatch, chirping the siren twice,
turning on your parking and interior lights for 30 seconds, unlocking the
doors, and disarming the system if it was armed.  The 2nd channel output
will not operate when the ignition switch is "on" unless the vehicle's door is
open.  If desired, the security system can be programmed to remain armed
when this feature is used, and connection of the 2nd channel may require
extra parts or installation.

To Silently Arm or Disarm the alarm, press and release the 

OPTION

button twice.  The siren’s confirmation chirps will not occur, and this opera-
tion simply reverses, or “toggles” the armed and disarmed status that the
system.

The sensor may be temporarily bypassed.  When arming the alarm

with the transmitter, within 3 seconds after the arming chirp press the

OPTION

 button.  The system will respond with another single chirp,

confirming that the sensor is bypassed.

The MAX-EDP also has a 3rd channel output which is similar to the 2nd

channel, but it does have some special operational design differences.  To
operate it, press and hold the transmitter 

OPTION

  and red “panic” buttons

together for 1 second.  Or, a programmable feature allows the pressing of
the “panic” button only to operate this output.

The differences are that 3rd channel output will  operate regardless of

the ignition switch being "on" or "off", and there is no audible or visual
confirmation.  Connection of the 3rd channel will vary, depending upon the
chosen application, and may require extra parts or installation.

There are also optional 4th channel and 5th channel outputs, which

are available if more remote control functions are desired.  These outputs
can be repurposed from two other system outputs, the factory arm and
disarm outputs, by an Installer Programmable Feature #9 (see page 42).

When these outputs are programmed to operate, pressing the transmitter

arm/lock” and “  buttons together will activate the 4th channel output.
Pressing the “disarm/unlock” and red “panic” buttons will activate the 5th
channel.  Or, if desired, the transmitter “panic” button can be programmed
by User Programming Feature #21 to operate any of these channels.

Page - 18

To a large extent the Omega MAX-EDP’s versatility is due to an incredible
array of programmable features- 33 main-system programmable features
which offer almost 100 choices of operational and interfacing options.

How to Program Features

To Enter Programing Mode and Change Features:

Page - 27

For easier management of the programmable features, they are divided

into two separate accessibility levels.  Features which allow the user to
customize the system’s operation according to their own choice are in one
group, and the features  which are installation related, or intended for the
installer’s use are in a second group.  The MAX-EDP system has 23 

User

Programmable Features

, and there are 10

 Installer Programmable Features

.

The vehicle ignition key and the Valet Switch are used to enter the

Programming Mode, then the transmitter or optional controller is used to
change features.  Once the system is in Programming Mode, a 10 second
period without programming activity will cause the system to automatically
exit Programming Mode.  Features can be selected in any order as desired.

The same basic “

Features Programming Mode

” is the means for changing

any of the features; the mode itself can be accessed as either the User level,
or the Installer level.

•The siren will chirp then sound briefly and the Status Light will

flash to confirm that the system is entering Programing Mode.

•In the case of accessing the Installer Mode, the siren chirp then

brief sounding will be heard at the fifth valet press, and then
again at the tenth valet switch press.

•The Status Light shows red color for User Programming, and

Green color for Installer programming.

•In either Programming Mode, if 10 seconds of no programming

activity occurs, the system will exit Programming Mode.  Pro-
gramming activity is the pressing of the Valet Switch or press-
ing a transmitter button once a feature is accessed.

 

5 times

  for User Programming     (Red Status Light)

               

OR

10 times

Installer Programming    (Green Status Light)

 

 When the desired Programming Mode is accessed, select a Feature > > >

 Step 3

Within 5 seconds, Press & Release the Valet Switch

 either:

 Step 2

Turn the ignition off.

 Step 1

Turn the vehicles’s ignition on.

Summary of Contents for MAX-EDP

Page 1: ...God This warranty limits the Company s liability to the repair or replacement of theproduct TheCompanyshallnotberesponsibleforremovaland orreinstallation charges damage to or theft of the vehicle or...

Page 2: ...O 4 Starter Interrupt Functions Alarm only L Off U Automatic O Alarm AntiGrind p 5 Ignition Activated Override OFF U ON L 6 Doors Lock With Ignition On ON L OFF U 7 Doors Unlock With Ignition Off ON...

Page 3: ...engine has started running Feature 10 Gasoline Or Diesel Engine Factory Default Setting Gasoline press arm lock button to program Option Diesel press disarm unlock button to program This feature chang...

Page 4: ...hich keeps the engine running after removing the ignition key After exiting the user must then arm the system locking the vehicle doors by pressing the arm lock button Only after this is done will the...

Page 5: ...nsmission equipped vehicles via a setup procedure which must be followed upon exiting the vehicle When this feature is turned on the operator must set the parking brake and then Feature 4 Turbo Timer...

Page 6: ...s also more suitable in some newer vehicles Some newer vehicles require a double pulse output to remotely unlock the doors and or to disarm a factory equipped security system which is what the Double...

Page 7: ...e Installer Programmable Features are accessed as the second level of features programming which is pressing the Valet Switch 10 times instead of 5 times when entering Programming Mode page 27 Caution...

Page 8: ...n the red color The system s reaction The parking and interior lights will flash once the siren will chirp once and the Status Light will begin to flash red confirming that the system is armed In addi...

Page 9: ...Last Door Arming process stops and will reset to start over when the point of entry is again closed All protected entries must be closed to initiate the Last Door Arming sequence To temporarily preve...

Page 10: ...ded Last Door Arming offers a high level of security since you do not have to remember to arm the security system every time you leave the vehicle and using it may entitle you to an insurance discount...

Page 11: ...cations and Zone Violation code will remain this way until the ignition key is turned on Page 34 Feature 11 Alarm Duration Factory Default Setting 30 Seconds press arm lock button to program Options 6...

Page 12: ...hin 5 seconds press and release the Valet Switch one time The system will disarm Step 2 Using the ignition key turn the vehicle s ignition switch on The number of Valet Switch presses which are requir...

Page 13: ...Factory Default Setting Off press disarm unlock button to program Option On press arm lock button to program This feature allows an activated system to be overridden and disarmed by simply turning th...

Page 14: ...it on demand before it times out again press and releasetogetherthetransmitter s arm lock and disarm unlock buttons The system will stop the engine and extinguish the parking lights This feature turn...

Page 15: ...mega MAX EDP is installed into a manual transmission vehicle Installer Program mable Feature 5 must be turned on Then whenever remote starting will be desired at a later time the following procedure m...

Page 16: ...he engine running normally from the ignition switch have the gear selector in park and your foot off of the brake pedal Press the Valet Switch twice the parking lights will flash once and the siren ch...

Page 17: ...he same number of times as the desired feature s number The siren will chirp and the Status Indicator Light will flash as many times as the Valet Switch was pressed to indicate the feature number whic...

Page 18: ...ressing the disarm unlock and red panic buttons will activate the 5th channel Or if desired the transmitter panic button can be programmed by User Programming Feature 21 to operate any of these channe...

Page 19: ...r optional controllers which are to operate the system at hand Turn the ignition on If the Unauthorized Transmitter Alert feature is on programming a transmitter or optional controller to the system w...

Page 20: ...er AlertTM UTA is a protection feature which may be turned on by the user see the next section How to Program Transmitters Whenthisprotectionfeatureisutilized wheneveratransmitter or optional 2 way co...

Page 21: ...jackingprotection features whose operation may be selectively activated by the ignition by an open door or by the transmitter All three are programmable and must be turned on to operate Once activated...

Page 22: ...ogrammed 6 2 Red Flashes pause 2 transmitters are programmed 9 2 Red Flashes Pause System was triggered by open hood or trunk 10 3 Red Flashes Pause System was triggered by an open door 21 Slowly Alte...