background image

button switches, each being labeled with an icon as to function.

However, a popular upgrade option supplementing the standard trans-

mitter is the Echo 2-way controller.  The Echo, in addition to operating your
system, also receives signals from the system, and displays a variety of
system conditions on its LCD screen.  A section of this booklet describes
operating the MAX-EDP with the Echo.

The Status Light and the Valet Switch

The location of the Valet Switch and the Status Light is determined by

the installer of the MAX-EDP system.  While the location of the Status Light
should be obvious, the Valet Switch should not.  The Valet Switch is
important to the user’s operation of the Omega MAX-EDP system.  It may
have been mounted separately from the Status Light in a hidden, yet
accessible location.

By itself, the Valet
Switch is a small,
round button, about
the size of a dime.

Please ensure that you and others who use your vehicle are
aware of the location of the Valet Switch and its uses.

Or, the Valet Switch and Status
Light may have been mounted
in special holder, which  is usu-
ally located below the dash.
This holder has the system’s
Status Light on front (upper im-
age) and the Valet Switch on its
bottom (lower image).

Page - 5

to be a door lock relay, or as medium-capacity ignition or accessory outputs,
if needed for remote starting use.

Page - 40

Feature #5   Stick Shift Remote Starting

Factory Default Setting

Off      (press “disarm/unlock” button to program)

Option:

On      (press “arm/lock” button to program)

This feature changes the parameters of the MAX-EDP’s remote start
operation to be suitable for manual transmission-equipped vehicles via a
“setup” procedure which must be followed upon exiting the vehicle.  When
this feature is turned on, the operator must set the parking brake and then

Feature #4   Turbo Timer

Factory Default Setting

Off
(press “arm/lock” button to program)

Options:
Run 1 Minute

(press “disarm/unlock” button to program)

Run 2 Minutes

(press 

OPTION

 button  to program)

Run 3 Minutes

(press red 

panic

 button  to program)

This feature, the operation of which is described on page 17, when turned
on configures the MAX-EDP to automatically keep the engine running
briefly after it is turned off.  This operation is designed specifically for
vehicles having turbocharged engines (the user may temporarily bypass
the feature if desired).
This feature should only be programmed by the installer, and the
operation of this feature depends on the correct connection of the safety
wire to the vehicle’s parking brake.  Please refer to the Installation Instruc-
tions manual for proper connection of this wire.

Feature #3   Horn Relay Functions

Factory Default Setting

Horn Output
(press “arm/lock” button to program)

Options:
Door Unlock

(press “disarm/unlock” button to program)

Ignition Output

(press 

OPTION

 button  to program)

Accessory Output

(press red 

panic

 button  to program)

This is the second of two built-in relays which can be programmed to
perform several different functions.  The primary function of this second
relay, is that it is available to operate the vehicle’s existing horn; either in
conjunction with the electronic siren, or in place of the siren.  Using both the
siren and the horn creates an extremely effective security system.

Optionally, if desired or needed, this relay can be programmed to be a

door unlock relay, or as additional medium-capacity ignition or accessory
outputs, if needed for remote starting use.

Summary of Contents for MAX-EDP

Page 1: ...God This warranty limits the Company s liability to the repair or replacement of theproduct TheCompanyshallnotberesponsibleforremovaland orreinstallation charges damage to or theft of the vehicle or...

Page 2: ...O 4 Starter Interrupt Functions Alarm only L Off U Automatic O Alarm AntiGrind p 5 Ignition Activated Override OFF U ON L 6 Doors Lock With Ignition On ON L OFF U 7 Doors Unlock With Ignition Off ON...

Page 3: ...engine has started running Feature 10 Gasoline Or Diesel Engine Factory Default Setting Gasoline press arm lock button to program Option Diesel press disarm unlock button to program This feature chang...

Page 4: ...hich keeps the engine running after removing the ignition key After exiting the user must then arm the system locking the vehicle doors by pressing the arm lock button Only after this is done will the...

Page 5: ...nsmission equipped vehicles via a setup procedure which must be followed upon exiting the vehicle When this feature is turned on the operator must set the parking brake and then Feature 4 Turbo Timer...

Page 6: ...s also more suitable in some newer vehicles Some newer vehicles require a double pulse output to remotely unlock the doors and or to disarm a factory equipped security system which is what the Double...

Page 7: ...e Installer Programmable Features are accessed as the second level of features programming which is pressing the Valet Switch 10 times instead of 5 times when entering Programming Mode page 27 Caution...

Page 8: ...n the red color The system s reaction The parking and interior lights will flash once the siren will chirp once and the Status Light will begin to flash red confirming that the system is armed In addi...

Page 9: ...Last Door Arming process stops and will reset to start over when the point of entry is again closed All protected entries must be closed to initiate the Last Door Arming sequence To temporarily preve...

Page 10: ...ded Last Door Arming offers a high level of security since you do not have to remember to arm the security system every time you leave the vehicle and using it may entitle you to an insurance discount...

Page 11: ...cations and Zone Violation code will remain this way until the ignition key is turned on Page 34 Feature 11 Alarm Duration Factory Default Setting 30 Seconds press arm lock button to program Options 6...

Page 12: ...hin 5 seconds press and release the Valet Switch one time The system will disarm Step 2 Using the ignition key turn the vehicle s ignition switch on The number of Valet Switch presses which are requir...

Page 13: ...Factory Default Setting Off press disarm unlock button to program Option On press arm lock button to program This feature allows an activated system to be overridden and disarmed by simply turning th...

Page 14: ...it on demand before it times out again press and releasetogetherthetransmitter s arm lock and disarm unlock buttons The system will stop the engine and extinguish the parking lights This feature turn...

Page 15: ...mega MAX EDP is installed into a manual transmission vehicle Installer Program mable Feature 5 must be turned on Then whenever remote starting will be desired at a later time the following procedure m...

Page 16: ...he engine running normally from the ignition switch have the gear selector in park and your foot off of the brake pedal Press the Valet Switch twice the parking lights will flash once and the siren ch...

Page 17: ...he same number of times as the desired feature s number The siren will chirp and the Status Indicator Light will flash as many times as the Valet Switch was pressed to indicate the feature number whic...

Page 18: ...ressing the disarm unlock and red panic buttons will activate the 5th channel Or if desired the transmitter panic button can be programmed by User Programming Feature 21 to operate any of these channe...

Page 19: ...r optional controllers which are to operate the system at hand Turn the ignition on If the Unauthorized Transmitter Alert feature is on programming a transmitter or optional controller to the system w...

Page 20: ...er AlertTM UTA is a protection feature which may be turned on by the user see the next section How to Program Transmitters Whenthisprotectionfeatureisutilized wheneveratransmitter or optional 2 way co...

Page 21: ...jackingprotection features whose operation may be selectively activated by the ignition by an open door or by the transmitter All three are programmable and must be turned on to operate Once activated...

Page 22: ...ogrammed 6 2 Red Flashes pause 2 transmitters are programmed 9 2 Red Flashes Pause System was triggered by open hood or trunk 10 3 Red Flashes Pause System was triggered by an open door 21 Slowly Alte...

Reviews: