Arming Bypass: Upon arming, if any system sensing circuit is inoperable,

that circuit only will automatically be bypassed.  When an unsecured
sensing circuit is in a bypassed state, all other normally operating circuits
will be protected.  Should the bypassed circuit become secured, it will
automatically be reinstated for protection 5 seconds later.  When certain
protection circuits are bypassed, such as the hood/trunk and impact sensor,
and the system is armed, it will indicate this by chirping the siren three time
and flashing the parking lights three times instead of the normal arming
indication of one chirp and one flash.

For example, should the trunk be open, you can still arm the  system with

the transmitter, and in this case the arming indicator will be 3 siren chirps
and 3 parking light flashes.  Arming Bypass will only operate when arming
the system with the transmitter.

Sensor Bypass: When arming the MAX-EDP system with the

transmitter, you may conveniently and easily temporarily deactivate the
impact sensor without affecting the system’s other sensing circuits. To
deactivate the sensor, arm the system by pressing the “arm/lock” button,
then press and release the  transmitter’s 

OPTION

 button within three

seconds.

  

You will hear a second siren chirp confirming that the security

system has armed without the sensor protecting the vehicle. The next time
the system is armed normally with one “arm/lock” button press, the sensor
will again be part of your protection.

Automatic “Last Door Arming” of the System

The MAX-EDP can also be programmed to automatically arm itself, and

in this process, to lock or not lock the doors.  When this feature is utilized,
closing the vehicle's last door will cause the siren to chirp once, the parking
and interior lights to flash once and the Status Light to start rapidly flashing
red.  Thirty seconds later the siren will chirp again and the lights will flash
again, the doors will lock (which is separately programmable) and the
Status Light will slow to a steady red flash, confirming that the security
system is fully armed.  If a point of entry is reopened before the single siren
chirp at 30 seconds, the Last Door Arming process stops, and will reset to
start over when the point of entry is again closed.  All protected entries must
be closed to initiate the Last Door Arming sequence.
To temporarily prevent the system from automatically Last Door Arming,

lock” button will simply rearm the system, and vice versa when pressing the
disarm/unlock” button.

Page - 9

Page - 36

Feature #19   Remote Activated Anti-Carjacking Protection

Factory Default Setting

Off      (press “disarm/unlock” button to program)

Option:

On      (press “arm/lock” button to program)

This form of Anti-Carjacking is initiated by a signal from the transmitter (or
optional 2-way controller).  The Anti-Carjacking protection, including the
three ways to initiate it are described on pages 24 & 25.

Feature #18   Door Activated Anti-Carjacking Protection

Factory Default Setting

Off      (press “disarm/unlock” button to program)

Option:

On      (press “arm/lock” button to program)

This form of Anti-Carjacking is initiated by a door being opened.  The Anti-
Carjacking protection, including the three ways to initiate it are described on
pages 24 & 25.

Feature #20   Open Door Warning Upon Arming

Factory Default Setting

Off      (press “disarm/unlock” button to program)

Option:

On      (press “arm/lock” button to program)

When this feature is turned on, if one of the vehicle's doors is open at the
time that the system is armed via the transmitter, the siren  will chirp 3 times
and the parking lights will flash 3 times instead of once.

Feature #21   Red “panic” Button Operation

Factory Default Setting

Panic
(press “arm/lock” button to program)

Options:
3rd Channel

(press “disarm/unlock” button  to program)

4th Channel

(press 

OPTION

 button  to program)

5th Channel

(press red 

panic

 button  to program)

This feature changes how the transmitter’s red “panic” button operates.
Normal operation, or the default setting, has the “panic” button operate the
Panic feature.  This feature allows changing it to operate the 3rd channel or
either of the two other optional channel outputs.  Panic can still be operated,
by the alternative methods of pressing either the “arm/lock” and “disarm/
unlock
” button for 3 seconds.

This feature will also operate with the optional 2-way controller in the

same fashion as described

Feature #22   Remote Start Run Time

Factory Default Setting

10 Minutes
(press “disarm/unlock” button to program)

Options:
5 Minutes

(press “arm/lock” button  to program)

Summary of Contents for MAX-EDP

Page 1: ...God This warranty limits the Company s liability to the repair or replacement of theproduct TheCompanyshallnotberesponsibleforremovaland orreinstallation charges damage to or theft of the vehicle or...

Page 2: ...O 4 Starter Interrupt Functions Alarm only L Off U Automatic O Alarm AntiGrind p 5 Ignition Activated Override OFF U ON L 6 Doors Lock With Ignition On ON L OFF U 7 Doors Unlock With Ignition Off ON...

Page 3: ...engine has started running Feature 10 Gasoline Or Diesel Engine Factory Default Setting Gasoline press arm lock button to program Option Diesel press disarm unlock button to program This feature chang...

Page 4: ...hich keeps the engine running after removing the ignition key After exiting the user must then arm the system locking the vehicle doors by pressing the arm lock button Only after this is done will the...

Page 5: ...nsmission equipped vehicles via a setup procedure which must be followed upon exiting the vehicle When this feature is turned on the operator must set the parking brake and then Feature 4 Turbo Timer...

Page 6: ...s also more suitable in some newer vehicles Some newer vehicles require a double pulse output to remotely unlock the doors and or to disarm a factory equipped security system which is what the Double...

Page 7: ...e Installer Programmable Features are accessed as the second level of features programming which is pressing the Valet Switch 10 times instead of 5 times when entering Programming Mode page 27 Caution...

Page 8: ...n the red color The system s reaction The parking and interior lights will flash once the siren will chirp once and the Status Light will begin to flash red confirming that the system is armed In addi...

Page 9: ...Last Door Arming process stops and will reset to start over when the point of entry is again closed All protected entries must be closed to initiate the Last Door Arming sequence To temporarily preve...

Page 10: ...ded Last Door Arming offers a high level of security since you do not have to remember to arm the security system every time you leave the vehicle and using it may entitle you to an insurance discount...

Page 11: ...cations and Zone Violation code will remain this way until the ignition key is turned on Page 34 Feature 11 Alarm Duration Factory Default Setting 30 Seconds press arm lock button to program Options 6...

Page 12: ...hin 5 seconds press and release the Valet Switch one time The system will disarm Step 2 Using the ignition key turn the vehicle s ignition switch on The number of Valet Switch presses which are requir...

Page 13: ...Factory Default Setting Off press disarm unlock button to program Option On press arm lock button to program This feature allows an activated system to be overridden and disarmed by simply turning th...

Page 14: ...it on demand before it times out again press and releasetogetherthetransmitter s arm lock and disarm unlock buttons The system will stop the engine and extinguish the parking lights This feature turn...

Page 15: ...mega MAX EDP is installed into a manual transmission vehicle Installer Program mable Feature 5 must be turned on Then whenever remote starting will be desired at a later time the following procedure m...

Page 16: ...he engine running normally from the ignition switch have the gear selector in park and your foot off of the brake pedal Press the Valet Switch twice the parking lights will flash once and the siren ch...

Page 17: ...he same number of times as the desired feature s number The siren will chirp and the Status Indicator Light will flash as many times as the Valet Switch was pressed to indicate the feature number whic...

Page 18: ...ressing the disarm unlock and red panic buttons will activate the 5th channel Or if desired the transmitter panic button can be programmed by User Programming Feature 21 to operate any of these channe...

Page 19: ...r optional controllers which are to operate the system at hand Turn the ignition on If the Unauthorized Transmitter Alert feature is on programming a transmitter or optional controller to the system w...

Page 20: ...er AlertTM UTA is a protection feature which may be turned on by the user see the next section How to Program Transmitters Whenthisprotectionfeatureisutilized wheneveratransmitter or optional 2 way co...

Page 21: ...jackingprotection features whose operation may be selectively activated by the ignition by an open door or by the transmitter All three are programmable and must be turned on to operate Once activated...

Page 22: ...ogrammed 6 2 Red Flashes pause 2 transmitters are programmed 9 2 Red Flashes Pause System was triggered by open hood or trunk 10 3 Red Flashes Pause System was triggered by an open door 21 Slowly Alte...