Step 2 Press and release the transmitter “arm/lock” and “disarm/unlock

buttons together.  The Status Light will begin flashing green, as the
MAX-EDP is now keeping the engine running. Do not press the
brake pedal from this point, and the parking brake must remain on.

Step 3 Within 2 minutes, turn off the ignition key, exit the vehicle and then

press the transmitter’s “arm/lock” button to lock the vehicle.  The
alarm will also arm, and the previously running engine will stop.  The
Status Light also changes to show the “armed” indication, flashing
slowly red, but every fourth flash will be green, indicating that the
system is “armed, and ready for remote starting”.

Step 1 With the engine running and foot on the brake, apply the parking

brake, put the transmission shifter in “neutral”, and remove your foot
from the brake.

From this point, the vehicle may be remote started provided that it is not

disturbed.  When ready to remote start, the activation of remote starting is
the same as previously described: press and release the transmitter’s “arm/
lock
” and “disarm/unlock” buttons together.

During the setup procedure, the parking brake must remain set, and the

regular brake pedal must not be pressed when and after the transmitter’s
arm/lock” and “disarm/unlock” buttons are pressed.  After exiting the
vehicle, the transmitter’s “arm/lock” button only must be used to secure the
vehicle.  Using any other transmitter button will produce the appropriate
system response, but the remote starting setup will be voided.

Once the system is fully setup for remote starting, it will start the engine

if the next transmitter operation is pressing the “arm/lock” and “disarm/
unlock
” buttons together.  If any other transmitter button is pressed the
remote starting setup will be voided.  If the armed alarm should be triggered
during this period, the remote starting setup condition will be voided.

Pit-Stop Feature:  This feature allows you to turn off the ignition switch,
remove your keys, leave the vehicle and lock your doors while leaving the
engine running.  To use this feature, have the engine running normally
from the ignition switch, have the gear selector in “park”, and your foot off
of the brake pedal.  Press the Valet Switch twice; the parking lights will
flash once and the siren chirps 5 times; then turn the ignition off.  The
engine will remain running for the programmed run time, or it will turn off if
another transmitter signal is received, a safety circuit is violated, or if the
Valet Switch is pressed.

This feature may be used anytime; it does not have to be specially

programmed to operate.

Page - 16

The User Programmable Features

Page - 29

Each of the Programmable Features is described in detail in the
following pages.  The User Programmable Features are described as
a first group, and the Installer Programmable Features as a second
group.  It is important to note that programmable features affect the
exact operation of the system, and that the descriptions of any
features utilized should be used to supplement the basic system
operations which were described in previous sections of this booklet.

This group of 23 User Programmable Features are all accessed as a
group in the first level of features’ programming.  These features have a
direct affect upon the system’s operations, so the programming and
operation of each are described following the list.

  1

SecureCode

  2

Last Door Arming

  3

Automatic Rearming

  4

Starter Interrupt Functions

  5

Ignition Activated Override

  6

Doors Lock With Ignition On

  7

Doors Unlock With Ignition Off

  8

Open Door Bypass To Previous Two Features

  9

Confirmation Chirps

10

Confirmation Chirp Volume

11

Activated Alarm Cycle

12

Lights On Upon Disarm

13

Disarm Alarm Upon Trunk Release

14

Arming Delay

15

Steady Siren Output / Pulsed Horn

16

Alarm Functions Bypass

17

Ignition Activated Anti-Carjacking Protection

18

Door Activated Anti-Carjacking Protection

19

Remote Activated Anti-Carjacking Protection

20

Open Door Warning Upon Arming

21

Red 

panic

 Button Operation

22

Remote Start Run Time

23

Steady / Flashing Lights During Remote Start

Use the step-by-step instructions on the previous two pages to change

any of these programmable features, along with the feature’s option
choices and related programming transmitter button assignment found in
the following individual feature descriptions.

Summary of Contents for MAX-EDP

Page 1: ...God This warranty limits the Company s liability to the repair or replacement of theproduct TheCompanyshallnotberesponsibleforremovaland orreinstallation charges damage to or theft of the vehicle or...

Page 2: ...O 4 Starter Interrupt Functions Alarm only L Off U Automatic O Alarm AntiGrind p 5 Ignition Activated Override OFF U ON L 6 Doors Lock With Ignition On ON L OFF U 7 Doors Unlock With Ignition Off ON...

Page 3: ...engine has started running Feature 10 Gasoline Or Diesel Engine Factory Default Setting Gasoline press arm lock button to program Option Diesel press disarm unlock button to program This feature chang...

Page 4: ...hich keeps the engine running after removing the ignition key After exiting the user must then arm the system locking the vehicle doors by pressing the arm lock button Only after this is done will the...

Page 5: ...nsmission equipped vehicles via a setup procedure which must be followed upon exiting the vehicle When this feature is turned on the operator must set the parking brake and then Feature 4 Turbo Timer...

Page 6: ...s also more suitable in some newer vehicles Some newer vehicles require a double pulse output to remotely unlock the doors and or to disarm a factory equipped security system which is what the Double...

Page 7: ...e Installer Programmable Features are accessed as the second level of features programming which is pressing the Valet Switch 10 times instead of 5 times when entering Programming Mode page 27 Caution...

Page 8: ...n the red color The system s reaction The parking and interior lights will flash once the siren will chirp once and the Status Light will begin to flash red confirming that the system is armed In addi...

Page 9: ...Last Door Arming process stops and will reset to start over when the point of entry is again closed All protected entries must be closed to initiate the Last Door Arming sequence To temporarily preve...

Page 10: ...ded Last Door Arming offers a high level of security since you do not have to remember to arm the security system every time you leave the vehicle and using it may entitle you to an insurance discount...

Page 11: ...cations and Zone Violation code will remain this way until the ignition key is turned on Page 34 Feature 11 Alarm Duration Factory Default Setting 30 Seconds press arm lock button to program Options 6...

Page 12: ...hin 5 seconds press and release the Valet Switch one time The system will disarm Step 2 Using the ignition key turn the vehicle s ignition switch on The number of Valet Switch presses which are requir...

Page 13: ...Factory Default Setting Off press disarm unlock button to program Option On press arm lock button to program This feature allows an activated system to be overridden and disarmed by simply turning th...

Page 14: ...it on demand before it times out again press and releasetogetherthetransmitter s arm lock and disarm unlock buttons The system will stop the engine and extinguish the parking lights This feature turn...

Page 15: ...mega MAX EDP is installed into a manual transmission vehicle Installer Program mable Feature 5 must be turned on Then whenever remote starting will be desired at a later time the following procedure m...

Page 16: ...he engine running normally from the ignition switch have the gear selector in park and your foot off of the brake pedal Press the Valet Switch twice the parking lights will flash once and the siren ch...

Page 17: ...he same number of times as the desired feature s number The siren will chirp and the Status Indicator Light will flash as many times as the Valet Switch was pressed to indicate the feature number whic...

Page 18: ...ressing the disarm unlock and red panic buttons will activate the 5th channel Or if desired the transmitter panic button can be programmed by User Programming Feature 21 to operate any of these channe...

Page 19: ...r optional controllers which are to operate the system at hand Turn the ignition on If the Unauthorized Transmitter Alert feature is on programming a transmitter or optional controller to the system w...

Page 20: ...er AlertTM UTA is a protection feature which may be turned on by the user see the next section How to Program Transmitters Whenthisprotectionfeatureisutilized wheneveratransmitter or optional 2 way co...

Page 21: ...jackingprotection features whose operation may be selectively activated by the ignition by an open door or by the transmitter All three are programmable and must be turned on to operate Once activated...

Page 22: ...ogrammed 6 2 Red Flashes pause 2 transmitters are programmed 9 2 Red Flashes Pause System was triggered by open hood or trunk 10 3 Red Flashes Pause System was triggered by an open door 21 Slowly Alte...