background image

OPTION

Pressing the

 “

OPTION

” 

button for two seconds can be used to activate

an extra output, known as the “2nd channel”, for an optional function
such as trunk release.

Pressing and releasing this button twice arms or disarms the system
without the confirmation chirps.

Pressing this button immediately after arming will leave the alarm
armed, but with the shock sensor feature bypassed.

Pressing the “

OPTION

” and “

panic

” buttons together operates the 3rd

channel output.

Red “panic” button

Pressing and holding the “panic” button for 3 seconds will activate the
remote Panic feature, but without locking or unlocking the doors.

The “panic” button can be reprogrammed so that it can operate an
additional 3rd channel output, instead of operating Panic.

           -  IMPORTANT  -

The MAX-EDP is the most versatile vehicle security system made.
It has many programmable features and includes built-in program-
mable relays, which can offer more features and operations which
are described in the basic system instructions.
To a large degree, these extra features and operations are config-
ured at the installation of the system.  Please read the sections of
this manual which explain programmable features, and please
consult your installer for specifics on how your system is config-
ured, and for installation options which may have used, or can be
added to system after installation.
EXAMPLE- the MAX-EDP can sound the vehicle’s horn in place of
or in addition to the electronic siren which is included with it.  But
the operations are described with the siren only.

Page - 7

The Installer Programmable Features

The second group of 10 features, the Installer Programmable Features,
are accessed as the second level of features’ programming, which is
pressing the Valet Switch 10 times instead of 5 times when entering
Programming Mode (page 27).  Caution:  These features have a critical
affect upon the system’s operations, and in many cases, also upon the
system’s wiring connections.  These features should NEVER be
changed, except by the installer or other qualified professional.  
The
companion Installation Instructions booklet should be consulted for wiring
connections associated with these features.

  1

Doorlocking Functions

  2

Light Relay Functions

  3

Horn Relay Functions

  4

Turbo Timer

  5

Manual Transmission Remote Starting

  6

“Tach Wire” or “Tachless” Starter Operations

  7

Extended Starter Cranking Time

  8

Programmable Remote Start Relay

  9

Arm, Disarm or Additional Channels

10

Gasoline or Diesel Engine

Use the step-by-step instructions on pages 27-28, but press the Valet
Switch 10 times at Step 3, to change any of the Installer Programmable
Features.  The feature’s option choices and related programming transmitter
button assignment found in the following individual feature descriptions.

Page - 38

Installer Programmable Features should only be used by the original
or other qualified installer, AND individual Installer Features should
only be used, where applicable, with the correct wiring connections.

Feature #1   Doorlocking Functions

Factory Default Setting

.8 Second Lock & Unlock Output
(press “arm/lock” button to program)

Options:
3 Second Lock & Unlock Output   

 

 (press “disarm/unlock” button to program)

Double Pulse Unlock Output

(press 

OPTION

 button  to program)

Total Closure Lock Output

(press red 

panic

 button  to program)

This single feature gives the installer several needed options, to match the
MAX-EDP’s doorlocking outputs to suite different vehicle requirements.

Summary of Contents for MAX-EDP

Page 1: ...God This warranty limits the Company s liability to the repair or replacement of theproduct TheCompanyshallnotberesponsibleforremovaland orreinstallation charges damage to or theft of the vehicle or...

Page 2: ...O 4 Starter Interrupt Functions Alarm only L Off U Automatic O Alarm AntiGrind p 5 Ignition Activated Override OFF U ON L 6 Doors Lock With Ignition On ON L OFF U 7 Doors Unlock With Ignition Off ON...

Page 3: ...engine has started running Feature 10 Gasoline Or Diesel Engine Factory Default Setting Gasoline press arm lock button to program Option Diesel press disarm unlock button to program This feature chang...

Page 4: ...hich keeps the engine running after removing the ignition key After exiting the user must then arm the system locking the vehicle doors by pressing the arm lock button Only after this is done will the...

Page 5: ...nsmission equipped vehicles via a setup procedure which must be followed upon exiting the vehicle When this feature is turned on the operator must set the parking brake and then Feature 4 Turbo Timer...

Page 6: ...s also more suitable in some newer vehicles Some newer vehicles require a double pulse output to remotely unlock the doors and or to disarm a factory equipped security system which is what the Double...

Page 7: ...e Installer Programmable Features are accessed as the second level of features programming which is pressing the Valet Switch 10 times instead of 5 times when entering Programming Mode page 27 Caution...

Page 8: ...n the red color The system s reaction The parking and interior lights will flash once the siren will chirp once and the Status Light will begin to flash red confirming that the system is armed In addi...

Page 9: ...Last Door Arming process stops and will reset to start over when the point of entry is again closed All protected entries must be closed to initiate the Last Door Arming sequence To temporarily preve...

Page 10: ...ded Last Door Arming offers a high level of security since you do not have to remember to arm the security system every time you leave the vehicle and using it may entitle you to an insurance discount...

Page 11: ...cations and Zone Violation code will remain this way until the ignition key is turned on Page 34 Feature 11 Alarm Duration Factory Default Setting 30 Seconds press arm lock button to program Options 6...

Page 12: ...hin 5 seconds press and release the Valet Switch one time The system will disarm Step 2 Using the ignition key turn the vehicle s ignition switch on The number of Valet Switch presses which are requir...

Page 13: ...Factory Default Setting Off press disarm unlock button to program Option On press arm lock button to program This feature allows an activated system to be overridden and disarmed by simply turning th...

Page 14: ...it on demand before it times out again press and releasetogetherthetransmitter s arm lock and disarm unlock buttons The system will stop the engine and extinguish the parking lights This feature turn...

Page 15: ...mega MAX EDP is installed into a manual transmission vehicle Installer Program mable Feature 5 must be turned on Then whenever remote starting will be desired at a later time the following procedure m...

Page 16: ...he engine running normally from the ignition switch have the gear selector in park and your foot off of the brake pedal Press the Valet Switch twice the parking lights will flash once and the siren ch...

Page 17: ...he same number of times as the desired feature s number The siren will chirp and the Status Indicator Light will flash as many times as the Valet Switch was pressed to indicate the feature number whic...

Page 18: ...ressing the disarm unlock and red panic buttons will activate the 5th channel Or if desired the transmitter panic button can be programmed by User Programming Feature 21 to operate any of these channe...

Page 19: ...r optional controllers which are to operate the system at hand Turn the ignition on If the Unauthorized Transmitter Alert feature is on programming a transmitter or optional controller to the system w...

Page 20: ...er AlertTM UTA is a protection feature which may be turned on by the user see the next section How to Program Transmitters Whenthisprotectionfeatureisutilized wheneveratransmitter or optional 2 way co...

Page 21: ...jackingprotection features whose operation may be selectively activated by the ignition by an open door or by the transmitter All three are programmable and must be turned on to operate Once activated...

Page 22: ...ogrammed 6 2 Red Flashes pause 2 transmitters are programmed 9 2 Red Flashes Pause System was triggered by open hood or trunk 10 3 Red Flashes Pause System was triggered by an open door 21 Slowly Alte...