![background image](http://html1.mh-extra.com/html/omega/hh-2000-series/hh-2000-series_operating-instructions-manual_737682002.webp)
2
2
31
31
Some of the options described may not apply to this
instrument. Please check the functions of the instrument
you have purchased before proceeding.
Some of the options described may not apply to this
instrument. Please check the functions of the instrument
you have purchased before proceeding.
X
Y
Instrument supplied pre-set to either °C or °F
Function available
Refer to rear of instrument for the temperature ranges.
X
Y
Instrument supplied pre-set to either °C or °F
Function available
Refer to rear of instrument for the temperature ranges.
INSTRUMENT OPERATION
BATTERIES
Two AA or equivalent cells (not supplied). Follow instructions on
reverse of instrument for fitting/replacement.
When
symbol appears on display, replace batteries.
INSTRUMENT OPERATION
BATTERIES
Two AA or equivalent cells (not supplied). Follow instructions on
reverse of instrument for fitting/replacement.
When
symbol appears on display, replace batteries.
PROBE CONNECTION
WARNING - Do not bring probe into contact with any service
connected to a hazardous voltage (i.e. a voltage exceeding 30
volts RMS or 42.4 volts peak with respect to either earth or
ground).
PROBE CONNECTION
WARNING - Do not bring probe into contact with any service
connected to a hazardous voltage (i.e. a voltage exceeding 30
volts RMS or 42.4 volts peak with respect to either earth or
ground).
GB
GB
ON - OFF
Press
key for on and
key for off. Automatic switch-off
after 12 minutes, unless any key is activated or the instrument is
in
mode. If
key is held when unit is switched
on, automatic switch-off function will be disabled until the unit is
switched off.
ON
OFF
LOG MAX/MIN
ON - OFF
Press
key for on and
key for off. Automatic switch-off
after 12 minutes, unless any key is activated or the instrument is
in
mode. If
key is held when unit is switched
on, automatic switch-off function will be disabled until the unit is
switched off.
ON
OFF
LOG MAX/MIN
IP65/IP67 RATING
The waterproof rating for this product will not be maintained
unless the screws holding the battery compartment are firmly
tightened when inserting or replacing batteries.
IP65/IP67 RATING
The waterproof rating for this product will not be maintained
unless the screws holding the battery compartment are firmly
tightened when inserting or replacing batteries.
Model
Model
Model
Model
HH2001KC
HH2001KC
K
K
HH2001TC
HH2001TC
T
T
HH2002K
HH2002K
K
K
Y
Y
HH2001P
HH2001P
PT100
PT100
HH2001K
HH2001K
K
K
HH2001LTC
HH2001LTC
T
T
HH2001PL
HH2001PL
PT100
PT100
HH2001KL
HH2001KL
K
K
HH2001A
HH2001A
KTJNRS
KTJNRS
HH2002A
HH2002A
KTJRNS
KTJRNS
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
X
X
X
X
X
X
HH2002AL
HH2002AL
KTJRNS
KTJRNS
Sensor
Sensor
Sensor
Sensor
2-Input
2-Input
2-Input
2-Input
SpeedRead
SpeedRead
SpeedRead
SpeedRead
C/F
C/F
C/F
C/F
Hold
Hold
Hold
Hold
Range Lock
Range Lock
Range Lock
Range Lock
Max/Min
Max/Min
Max/Min
Max/Min
Logging
Logging
Logging
Logging
HH 2001P Wiring Diagram
HH 2001P Wiring Diagram
Black
Black
Red
Red
For 3 wire RTD probes - one Red wire
connects to both pins 2 and 4.
For 2 wire RTD probes - one Red wire
connects to both pins 2 and 4
and one Black wire connects to
pins 1 and 3.
For 3 wire RTD probes - one Red wire
connects to both pins 2 and 4.
For 2 wire RTD probes - one Red wire
connects to both pins 2 and 4
and one Black wire connects to
pins 1 and 3.
Black
Black
Red
Red
pin 1
pin 1
pin 3
pin 3
pin 4
pin 4
pin 2
pin 2
TA 4F
(wiring side)
TA 4F