background image

28

28

5

5

LOGGING ON DEMAND

This function allows readings to be stored as and when required.
A maximum of 50 readings can be stored this way.
When ready to store a reading press

key.

,

symbols

and will appear on the display. It is possible to enter up to a
four digit reference number including decimal point. Press

key

to enter and store reading, time, date and reference number.
Instrument will return to standard mode, however

symbol will

remain on display until data is erased.

NE

0

LOGGING ON DEMAND

This function allows readings to be stored as and when required.
A maximum of 50 readings can be stored this way.
When ready to store a reading press

key.

,

symbols

and will appear on the display. It is possible to enter up to a
four digit reference number including decimal point. Press

key

to enter and store reading, time, date and reference number.
Instrument will return to standard mode, however

symbol will

remain on display until data is erased.

NE

0

PRESET INTERVAL LOGGING

This function allows readings to be taken automatically at a preset
time interval.
NOTE: If data is already stored, as signified by the

or

symbols appearing on display, this function will not operate.

Instrument will continue logging until a maximum of 250 readings
are taken or data is down-loaded.

Press

key.

symbol and

will appear on the display.

Enter required time interval in hh:mm (ie, in order to take a
reading every 1 minute, key in 0001) and press

key. Current

reading will return to display and

symbol will remain on

display.

NE

0000

PRESET INTERVAL LOGGING

This function allows readings to be taken automatically at a preset
time interval.
NOTE: If data is already stored, as signified by the

or

symbols appearing on display, this function will not operate.

Instrument will continue logging until a maximum of 250 readings
are taken or data is down-loaded.

Press

key.

symbol and

will appear on the display.

Enter required time interval in hh:mm (ie, in order to take a
reading every 1 minute, key in 0001) and press

key. Current

reading will return to display and

symbol will remain on

display.

NE

0000

LOGGING

These models have functions that enable the user to store and
retrieve up to 250 readings and output such to a PC or Epson
compatible printer via Omega’s Infra-red HHP-2000DL. Omega
also offers MLWIN, a customised Windows™ software package.
Note: Some functions may be inhibited while information is stored
in either Auto, Manual or Max/Min modes. This is to prevent
inadvertent parameter mixing whilst in any of the above modes.
To re-activate these functions please delete any stores
information by following the "Output of data" section.

LOGGING

These models have functions that enable the user to store and
retrieve up to 250 readings and output such to a PC or Epson
compatible printer via Omega’s Infra-red HHP-2000DL. Omega
also offers MLWIN, a customised Windows™ software package.
Note: Some functions may be inhibited while information is stored
in either Auto, Manual or Max/Min modes. This is to prevent
inadvertent parameter mixing whilst in any of the above modes.
To re-activate these functions please delete any stores
information by following the "Output of data" section.

ADVANCED FUNCTIONS
The following additional functions apply to models
HH2001KL, HH2001LTC, HH2001PL, HH2002AL

ADVANCED FUNCTIONS
The following additional functions apply to models
HH2001KL, HH2001LTC, HH2001PL, HH2002AL

OUTPUT OF DATA

This feature will only function if either the

or

symbols are

displayed.
To view data press

key, then and

keys. The first stored

reading will be displayed. Press

key to view successively

stored readings and any other key to return to normal mode.

1

OUTPUT OF DATA

This feature will only function if either the

or

symbols are

displayed.
To view data press

key, then and

keys. The first stored

reading will be displayed. Press

key to view successively

stored readings and any other key to return to normal mode.

1

SETTING INTERNAL CLOCK

Press d

(•) key and the

and

symbols will

appear on display with the current year and month settings

Key in new year and month if desired and press

key to accept.

Display will show current date of month setting (DD). Key in new
value if desired and press

key to accept.

Display will show current hours and minutes setting (24 hour
clock). Key in new values if desired and press

key to accept.

Instrument will then return to normal mode.

NE

ecimal point

(YYMM).

SETTING INTERNAL CLOCK

Press d

(•) key and the

and

symbols will

appear on display with the current year and month settings

Key in new year and month if desired and press

key to accept.

Display will show current date of month setting (DD). Key in new
value if desired and press

key to accept.

Display will show current hours and minutes setting (24 hour
clock). Key in new values if desired and press

key to accept.

Instrument will then return to normal mode.

NE

ecimal point

(YYMM).

®

®

omega.com

®

®

omega.com

OMEGAnet On-Line Service

http://www.omega.com

®

OMEGAnet On-Line Service

http://www.omega.com

®

Internet e-mail

[email protected]

Internet e-mail

[email protected]

Servicing North America:

Servicing North America:

For immediate technical or application assistance:

For immediate technical or application assistance:

Servicing Europe:

Servicing Europe:

USA:

ISO 9001 Certified

USA:

ISO 9001 Certified

Canada:

Canada:

USA and Canada:

USA and Canada:

Mexico and
Latin America:

Mexico and
Latin America:

Benelux:

Benelux:

Postbus 8034, 1180 LA Amstelveen, The Netherlands
Tel: (31) 20 6418405
Toll Free in benelux: 0 800 0993344
e-mail: [email protected]

Postbus 8034, 1180 LA Amstelveen, The Netherlands
Tel: (31) 20 6418405
Toll Free in benelux: 0 800 0993344
e-mail: [email protected]

Czech Republic:

Czech Republic:

France:

France:

Germany/Austria:

Germany/Austria:

United Kingdom:

ISO 9002 Certified

United Kingdom:

ISO 9002 Certified

One Omega Drive, River Bend Technology Centre,
Northbank, Irlam, Manchester M44 5EX, England
Tel: 44 (161) 777-7711
Toll Free in England: 0800-488-488
e-mail: [email protected]

One Omega Drive, River Bend Technology Centre,
Northbank, Irlam, Manchester M44 5EX, England
Tel: 44 (161) 777-7711
Toll Free in England: 0800-488-488
e-mail: [email protected]

Daimlerstrasse 26, D-85392 Deckenpfronn, Germany
Tel: 49 (07056) 3017
Toll Free in German: 0130 11 21 66
e-mail: [email protected]

Daimlerstrasse 26, D-85392 Deckenpfronn, Germany
Tel: 49 (07056) 3017
Toll Free in German: 0130 11 21 66
e-mail: [email protected]

9 rue Denis Papin, 78190 Trappes
Tel: (33) 130-621-400
Toll Free in France: 0800-4-06342
e-mail: [email protected]

9 rue Denis Papin, 78190 Trappes
Tel: (33) 130-621-400
Toll Free in France: 0800-4-06342
e-mail: [email protected]

ul. Rude armady 1868, 73301 Karvina-Hranice
Tel: 420 (69) 6311899
Toll Free: 0800-1-66342

ul. Rude armady 1868, 73301 Karvina-Hranice
Tel: 420 (69) 6311899
Toll Free: 0800-1-66342

Sales Service:1-800-826-6342 / 1-800-TC-OMEGA
Customer Service: 1-800-622-2378 / 1-800-622-BEST
Engineering Service: 1-800-872-9436/1-800-USA-WHEN
TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA

SM

SM

SM

Sales Service:1-800-826-6342 / 1-800-TC-OMEGA
Customer Service: 1-800-622-2378 / 1-800-622-BEST
Engineering Service: 1-800-872-9436/1-800-USA-WHEN
TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA

SM

SM

SM

Tel: (95) 800-826-6342
En Español: (95) 203-359-7803

Tel: (95) 800-826-6342
En Español: (95) 203-359-7803

FAX: (95) 203-359-89-8
Email: [email protected]

FAX: (95) 203-359-89-8
Email: [email protected]

FAX: (31) 20 6434643

FAX: (31) 20 6434643

FAX: 420 (69) 6311114
Email: [email protected]

FAX: 420 (69) 6311114
Email: [email protected]

FAX: (33) 130-699-120

FAX: (33) 130-699-120

FAX: 49 (07056) 8540

FAX: 49 (07056) 8540

FAX: 44 (161) 777-6622

FAX: 44 (161) 777-6622

976 Bergar
Laval (Quebec) H7L 5A2
Tel: (514) 856-6928
e-mail: [email protected]

976 Bergar
Laval (Quebec) H7L 5A2
Tel: (514) 856-6928
e-mail: [email protected]

One Omega Drive, Box 4047
Stamford, CT 06907-0047
Tel: (203) 359-1660
e-mail: [email protected]

One Omega Drive, Box 4047
Stamford, CT 06907-0047
Tel: (203) 359-1660
e-mail: [email protected]

FAX: (203) 359-7700

FAX: (203) 359-7700

FAX: (514) 856 6886

FAX: (514) 856 6886

Summary of Contents for HH-2000 SERIES

Page 1: ...erived from Type K Serial No This instrument has been calibrated in Tested by Norm IP65 Norm IP67 This instrument has been designed to meet environmental condition TEST RESULTS Model Type K to BS 4937 DIN 43710 Type T to BS 4937 DIN 43710 Thermistor PT100 to BS 1904 Types T J N R and S derived from Type K Serial No This instrument has been calibrated in Tested by Norm IP65 Norm IP67 This instrumen...

Page 2: ...duct will not be maintained unless the screws holding the battery compartment are firmly tightened when inserting or replacing batteries Model Model Model Model HH2001KC HH2001KC K K HH2001TC HH2001TC T T HH2002K HH2002K K K Y Y HH2001P HH2001P PT100 PT100 HH2001K HH2001K K K HH2001LTC HH2001LTC T T HH2001PL HH2001PL PT100 PT100 HH2001KL HH2001KL K K HH2001A HH2001A KTJNRS KTJNRS HH2002A HH2002A K...

Page 3: ... surface of food produce not suitable for use with between pack probe Insert probe and press key The symbol will appear and the display will flash until the correct reading appears and the symbol will be displayed This reading will automatically be held Press key to return to normal mode If it is not possible to obtain a faster reading due to the similarity of probe tip temperature and temperature...

Page 4: ...isplay Press key to display the average temperature since the MAX MIN mode was activated and symbol will appear on display Press key again to return to actual temperature display NOTE To reset MAX MIN recorder function switch the instrument off RANGE LOCK Models HH2001A HH2001K HH2001KL HH2001P HH2001PL HH2002A HH2002AL All instruments have a 0 1 resolution from and a 1 resolution outside this ran...

Page 5: ...lay with the current year and month settings Key in new year and month if desired and press key to accept Display will show current date of month setting DD Key in new value if desired and press key to accept Display will show current hours and minutes setting 24 hour clock Key in new values if desired and press key to accept Instrument will then return to normal mode NE ecimal point YYMM SETTING ...

Page 6: ...fication strict liability or otherwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold by OMEGA is not intended to be used nor shall it be used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical a...

Page 7: ...registrate oppure fino a che i dati non vengono scaricati USCITA DATI Questa caratteristica funzionerà solamente se i simboli o appaiono sul display Per visualizzare i dati premere una volta il tasto e poi premere i tasti e per visualizzare letture memorizzate successivamente e premere qualsiasi altro tasto per ritornare alla modalità normale Per trasmettere dati ad un PC premere il tasto una volt...

Page 8: ...na la modalità non verrà azzerato anche dopo aver cancellato il circuito aperto Se si é fuori portata di gomma sea sotto o sopra do il simbolo out apparirá sul display MAX MIN O C REGISTRAZIONE SU RICHIESTA Questa funzione da la possibilità di memorizzare letture come e quando lo si richiede Quando si è pronti a memorizzare una lettura premere i tasti simboli e appariranno sullo display E possibil...

Page 9: ...i differenziali Il canale selezionato apparirà sul display e verrà richiamato la prossima volta che lo strumento verrà riattivato NOTA La selezione del canale non funzionerà se il display si trova in modalità oppure IMMISSIONE DIFFERENZIALE Modelli HH2002A HH2002AL HH2002K A B A B A B HOLD MAX MIN Premendo il tasto di selezione di canale si può regolare il termometro in modo da poter leggere l imm...

Page 10: ...ie Es kann sein dass einige Funktionen während des ZEIT EINSTELLEN Taste für 5 Sekunden gedrückt halten und sowie das Jahr und der Monat sind im Display angezeigt Das Jahr und der Monat können auf Wunsch geändert werden Taste drücken Die Zeit wird angezeigt und kann auf Wunsch geändert werden Taste drücken Das Gerät kehrt zum normalen Modus zurück NE RETROILLUMINAZIONE Premere il tasto mantenendol...

Page 11: ... HH2002AL HH2002K Modelle HH2001T HH2001LTC Modelle HH2001P HH2001PL 1 Digit 0 1 der Anzeige 0 2 C 0 4 F unter 100 C 148 F 0 5 der Anzeige 0 2 C 0 4 F über 100 C 148 F R S Typ thermocouple 0 2 C 0 4 F von 20 C und 70 C 4 F und 158 F 0 1 der Anzeige 0 2 C 0 4 F sonst 0 2 der Anzeige 0 1 C 0 2 F zwischen 150 C und 800 C 238 F und 1472 F SpeedRead die Genauigkeit ist von Klasse 0 5 bis 2 reduziert CE...

Page 12: ...ion sélectionné sera affiché pendant la transmission Après la transmission l appareil retournera en mode normal et l enregistrement automatique sera arrêté Pour effacer les données en mémoire appuyez sur la touche une fois puis sur la touche et Il y aura un certain retard pour éviter tout effacement accidentel Les symboles et ne seront plus affichés L appareil retournera en mode normal Si aprés av...

Page 13: ...férence L appareil retournera en mode normal sera affiché jusqu à ce que les données soient effacées NE 0 ENREGISTREMENT PRÉRÉGLÉ Cette fonction permet l enregistrement de données à des intervalles préprogrammés NOTE si les données ont déjà été mémorisées et ou sont affichées vous ne pouvez pas utiliser cette fonction Appuyez sur la touche et seront affichés Introduire le temps d enregistrement et...

Page 14: ...001KL HH2001P HH2001PL HH2002A HH2002AL A R Todos los instrumentos tienen una resolución de 0 1 entre 199 9 a 199 9 C 199 9 a 392 8 F y una resolución de 1 fuera de este rango Para fijar la resolución en 1 pulsar la tecla X X MESURE C F Modèles HH2001A HH2001K HH2001KL HH2001P HH2001PL HH2002A HH2002AL HH2002K Pour choisir l échelle désirée appuyez sur le bouton C ou F est visualisé sur l afficheu...

Page 15: ...les de año y mes Si es necesario teclear al año y mes y pulsar la tecla para aceptarlos Se visualiza el ajuste de la fecha actual Si se desea teclear la fecha y pulsar la tecla para aceptarla Se visualiza el ajuste de la hora y minutos actuales Si es necesario teclear nuevos valores y pulsar la tecla para aceptarlos El instrumento luego retorna a su modalidad normal NE AJUSTE DEL RELOJ INTERNO Pul...

Page 16: ... encima de 100 C 148 F 0 5 lectura 0 2 C 0 4 F por debajo de 100 C 148 F Termopar tipo R S 0 2 C 0 4 F en el rango 20 C to 70 C 4 F to 158 F 0 1 lectura 0 2 C 0 4 F en el resto 0 2 lectura 0 1 C 0 2 F en el rango 150 C to 800 C 238 F to 1472 F SpeedRead Esta funcion reduce exactitud de clase 0 5 to 2 CEN TC141 WG12 N42E 2 C Modelos HH2001A HH2001K HH2001KL HH2002A HH2002AL HH2002K Modelos HH2001T ...

Reviews: