![background image](http://html1.mh-extra.com/html/omega/crime-guard-650i6/crime-guard-650i6_installation-instructions-manual_4031503007.webp)
siren requires. When programming this feature for using the output for the vehicle’s
horn, the optional setting produce pulsed output on the system’s siren wire, in
three different pulse timings, which allow a degree of customizing of the horn’s
sound during the alarm activation.
Page - 30
Feature #16 Alarm Functions Bypass
Factory Default Setting
Off (
press
“disarm/unlock” button to program
)
Option:
On (
press
“arm/lock” button to program
)
This feature converts the system into a strictly Remote Keyless Entry System by
eliminating all antitheft alarm-oriented operations and features. When this feature
is programmed on, the Crime Guard has remote keyless entry operation only.
Factory Default Setting
Off (
press
“disarm/unlock” button to program
)
Option:
On (
press
“arm/lock” button to program
)
This form of Anti-Carjacking is initiated by the ignition key being turned on. All
3 forms of Anti-Carjacking protection are described in the Operation Guide.
Feature #19 Remote Activated Anti-Carjacking Protection
Factory Default Setting
Off (
press
“disarm/unlock” button to program
)
Option:
On (
press
“arm/lock” button to program
)
This form of Anti-Carjacking is initiated by a signal from the controller or
transmitter. All 3 forms of Anti-Carjacking protection are described in the
Operation Guide.
Feature #18 Door Activated Anti-Carjacking Protection
Factory Default Setting
Off (
press
“disarm/unlock” button to program
)
Option:
On (
press
“arm/lock” button to program
)
This form of Anti-Carjacking is initiated by a door being opened. All 3 forms of
Anti-Carjacking protection are described in the Operation Guide.
Feature #20 Open Door Warning Upon Arming
Factory Default Setting
Off (
press
“disarm/unlock” button to program
)
Option:
On (
press
“arm/lock” button to program
)
When this feature is turned on, if one of the vehicle's doors is open at the time that
the system is armed via the controller or transmitter, the siren will chirp 3 times and
the parking lights will flash 3 times instead of once.
Feature #17 Ignition Activated Anti-Carjacking Protection
Feature #21 “III” Button Operation
Factory Default Setting
3rd Channel
(
press
“arm/lock” button to program
)
the ignition switch, the supply wire behind the fuse block or the fuse/junction block.
Never just insert the Red wire or any other security system wire behind a fuse. Also,
please note that connecting directly to the battery's Positive terminal will expose
this connection to failure due to a corrosive environment unless the connection has
a protective coating.
Yellow Wire - (Ignition Input):
The Yellow wire is an ignition "on"
input to the security system. This connection is critical to the proper operation of
many of the security system's features.
CONNECTION:
This wire supplies Positive 12 Volts to the control module
whenever the ignition switch is "on". This connection should be made at the
ignition switch harness, to the primary ignition circuit. Primary ignition has 0 Volts
when the ignition key is in the "Lock", "Off" and "Accessory" positions; and
Positive 12 Volts in the "Run" and "Start" positions. Locate the correct wire at the
ignition switch harness and securely splice the Yellow wire to it.
Orange Wire - (Negative Output While Armed); Includes the
thick Red & White Wires attached to the relay socket - (Starter
Interrupt):
The Orange wire is a starter interrupt output, which is active when
the security system is in an armed state; the relay that it is attached to the Orange
wire prevents the starter from engaging, if a starting attempt is made while the
system is armed.
CONNECTION:
The typical starter interrupt is shown here-
Page - 7
Dash-
mounted
Ignition
Switch
Relay
Starter Disable White
wire to the
Starter Solenoid
side of the cut
wire.
Starter
Solenoid
Starter
Motor
Starter Disable Red
wire to the Ignition
Switch side of the
cut wire.
Starter
Disable
Socket
5-Pin
Connector
Socket
Orange
wire
Crime Guard
Control
Module
Starter Disable
Connections