Toll Free 1-888-658-1658 www.outdoorlivingtoday.com [email protected]
Page 13
30.
Attach
Horizontal Wall Extendor
Braces
(3/4” x 3 1/2” x 26”/30”/60”) to
Framing of Extendor and Bottom walls.
Start with High Wall Side and attach 60”
and 26” long pieces with 10 - 1 1/4”
screws. Pieces should be flush with top
of Extendor Wall Framing. Alternate
screws into both pieces of framing.
Complete Front and Rear walls (60” and
30” pieces).
31.
When all walls are attached together, check alignment with the floor. Bottom wall framing should
sit flush with outside floor framing. When positioned correctly, fasten bottom wall plates to floor using
4 - 2 1/2” screws per wall panel.
Important:
If walls are not lining up and appear higher or lower than
each other, your floor may not be LEVEL. Please check the level of your floor. You may need to make
slight adjustments to level your floor before proceeding.
Confirm 32” wide Door Opening prior to attaching walls to floor.
Angle
screws into perimeter
Floor Joists.
125 1/4”
125 1/4”
Bottom Wall
Framing
32”
Advice:
Prior to fastening walls and
installing rafters, take time to confirm your
walls are level, square and plumb.
Measure diagonal at top and bottom of
walls corner-to-corner. This should be
approximately 125 1/4”. More importantly, if
measurements are not within 1/4”, your
walls are not square. Adjusting now will
make it easier to the roof section later
.