2KR/2KS
1-5-30
1-5-7
Fuser section
(1) Detaching and refitting the fuser unit
Follow the procedure below to check or replace the fuser unit.
Procedure
1. Remove the clip holder.
2. Open the front cover and left cover 1.
3. Remove four screws and remove front left
cover.
Figure 1-5-60
4. Remove the screw and remove the fuser
unit.
5. Check or replace the fuser unit and install
the unit.
6. Perform maintenance mode U167 to clear
the counter value (see page 1-3-52).
Figure 1-5-61
Front left cover
Clip holder
Screw
Screws
Screw
Screw
Fuser unit