2FD/2FF/2FG
1-5-44
(17) Image is out of
focus.
Causes
1. Defective image scanning unit.
2. Drum condensation.
Causes
Check procedures/corrective measures
1. Defective image scanning unit.
Replace the image scanning unit (see page 1-6-30).
2. Drum condensation.
Perform the drum refresh operation.
(15) Image is partly miss-
ing.
Causes
1. Paper damp.
2. Paper creased.
3. Drum condensation.
4. Flawed drum.
Causes
Check procedures/corrective measures
1. Paper damp.
Check the paper storage conditions.
2. Paper creased.
Replace the paper.
3. Drum condensation.
Perform the drum refresh operation.
4. Flawed drum.
Perform the drum refresh operation. If the drum is flawed, replace
the drum unit.
(16) Fixing is poor.
Causes
1. Wrong paper.
2. Defective pressure springs.
3. Flawed press roller.
4. Defective fixing heater S.
Causes
Check procedures/corrective measures
1. Wrong paper.
Check if the paper meets specifications.
2. Defective pressure springs.
Replace the pressure springs.
3. Flawed press roller.
Replace the press roller (see page 1-6-63).
4. Defective fixing heater S.
Replace the fixing heater S (see page 1-6-63).