2FD/2FF/2FG
1-3-16
3. Open the drawer of the paper feeder and loosen the three screws securing the adjuster.
A and B: test pattern output examples
4. If the test pattern output example looks like A, move the adjuster in the direction of the white arrow (
e
) and retighten
the three screws.
If the test pattern output example looks like B, move the adjuster in the direction of the black arrow (
b
) and retighten
the three screws.
5. Output the test pattern again.
6. Repeat steps 3 to 5 until the centers of the paper and the test pattern are aligned.
A
B
Adjuster
Screws
Drawer
Figure 1-3-27
*If necessary, please fix the cassette cursor
with the screws included in the machine box.