2FD/2FF/2FG
1-6-28
(9) Adjusting magnification of the scanner in the auxiliary scanning direction
Perform the following adjustment if the magnification in the auxiliary scanning direction is not correct.
U053
(P. 1-4-22)
U070
(P. 1-4-25)
U065
(auxiliary scanning
direction)
U065
(main scanning
direction) (P. 1-6-27)
Caution:
Before making the following adjustment, ensure that the above adjustments have been made in maintenance mode.
Procedure
Enter maintenance mode.
Enter “065” using the numeric keys.
Yes
No
Start
Press the interrupt key.
Place an original and press
the start key to make a test copy.
Is the image correct?
Setting range: –25 – +25
Initial setting: 1
Changing the value by 1 changes
the magnification by 0.1%.
Increasing the value makes
the image longer, and decreasing it
make the image shorter.
For copy example 1, increase the
value using the cursor up key.
For copy example 2, decrease the
value using the cursor down key.
Press the start key.
The new setting
is stored.
Press the start key.
Select “SUB SCAN ADJ”
(auxiliary scanning direction).
End
Press the stop/clear key to
exit maintenance mode.
Original
Copy
example 1
Copy
example 2
Figure 1-6-55