2FD/2FF/2FG
1-3-32
Figure 1-3-68
Signal cable of
the finisher
Signal cable of
the switchback unit
Connecting the signal cable
1. Connect the signal cable of the finisher to the
copier. If the switchback unit has been
installed, connect the signal cable of the
switchback unit, as well.
2. Insert the copier power plug to the wall outlet
and turn the power switch on.
3. Make test copies and check that the finisher
and the switchback unit operate correctly.
Setting the booklet stapling position
1. Enter the maintenance mode and run U246.
2. Select "Saddle finisher" and press the start
key.
3. Select the size to be set. The selected item is
displayed in reverse.
4. Change the setting using the cursor up/down
keys.
a: Decrease the preset value.
b: Increase the preset value.
*Setting range: –125 to +125
Initial setting: 0
Change in value per step: Approx. 0.25 mm
5. Press the start key. The value is set.
6. Press the stop/clear key twice.
7. Run U001 to exit the maintenance mode.
a
b
Figure 1-3-69