4065 Table Saw
Belt Replacement
1.
Disconnect the saw from the power source.
2.
Remove the motor access panel.
3.
Slightly loosen the four motor mounting nuts
so the motor can be temporarily raised to
the highest position. Retighten the nuts.
4.
Remove the belt by walking the belt off the
arbor pulley and then sliding the belt
through the gap between the motor pulley
and the elevation bracket (#32 in the parts
diagram).
5.
Install the new belt. First, slide the belt
through the gap between the motor pulley
and the elevation bracket, then walk the belt
and make sure it sits correctly on the motor
pulley and arbor pulley.
6.
Loosen the motor mounting nuts to tighten
the belt, then retighten the nuts to secure
the motor.
7.
Reinstall the motor access panel to complete
the process.
IMPORTANT
Do not over tighten the belt, as it can accelerate wear and tear of the belt and
the bearings.
Summary of Contents for 4065
Page 2: ......
Page 10: ...10 Page Oliver Machinery 4065 Table Saw Identification...
Page 11: ...4065 Table Saw OLIVERMACHINERY NET 11 Page...
Page 67: ...4065 Table Saw OLIVERMACHINERY NET 67 Page Parts List Table and Blade Guard...
Page 68: ...68 Page Oliver Machinery 4065 Table Saw Cabinet...
Page 69: ...4065 Table Saw OLIVERMACHINERY NET 69 Page Motor and Blade Lift Assembly...
Page 70: ...70 Page Oliver Machinery 4065 Table Saw Trunnion Assembly...
Page 71: ...4065 Table Saw OLIVERMACHINERY NET 71 Page Rails...
Page 72: ...72 Page Oliver Machinery 4065 Table Saw Extension Table...
Page 73: ...4065 Table Saw OLIVERMACHINERY NET 73 Page Rip Fence Assembly...
Page 74: ...74 Page Oliver Machinery 4065 Table Saw Miter Gauge...
Page 84: ...84 Page Oliver Machinery 4065 Table Saw Maintenance Record Date Task Operator...
Page 85: ...4065 Table Saw OLIVERMACHINERY NET 85 Page Notes...
Page 87: ......