![background image](http://html1.mh-extra.com/html/oldham/olct-200/olct-200_user-manual_3711996027.webp)
27
OLCT 200 User Manual |
27
Figure 2-12: 10-0250 Isolated 4-20mA Output Option
2.9 HART Communication 10-0351 Option
Description:
The optional 10-0351 HART modem board, figure 2-13, supplies ability to access and
alter process variables of the OLCT 200 using a HART handheld device. This board is
stacked behind the 10-0232 Display Assembly. Addition of this option requires 3-wire
mode 4-20mA operation and thereby requires the 10-0233 I/O Power Supply board.
This is since the modem’s driver circuits require much more power than 2-wire 4-20mA
loops can deliver. When installed in an OLCT 200 transmitter, power and common are
run to the I/O board and TB1 supplies 4-20 mA output. Common on the HART modem
and the I/O board are tied together.
In most applications the power is supplied from the controller that is receiving the 4-20
mA output. In these applications only three wires are required since common is shared
from the I/O board to the HART modem through the ribbon cable. Power is connected
to the I/O board and the signal connected to TB1 on the HART board.
If the 4-20 mA output is going to another device other than the one that is powering it,
or the transmitter has its own local power supply, both + and
– on at TB1 on the HART
board must be utilized for the 4-20 mA loop to function.
IMPORTANT
The 4-20 mA output must be loaded with at least 250 ohms of impendence for the
HART modem to transmit process variables. Some devices receiving the 4-20 mA
output have a large enough terminating resistor installed from the factory, but others
may need additional resistance added. This is accomplished by adding a resistor in
U8
TB1
P1
FUSE
Assy: 10-0250
1
2
3
4
-
+
-
+
Isolated 4-20mA Output Option
1/2A
Summary of Contents for OLCT 200
Page 4: ...OLCT 200 User Manual 4...
Page 14: ...OLCT 200 User Manual 14 Figure 2 3a Outline Drawing OLCT 200 Wired Models...
Page 19: ...OLCT 200 User Manual 19 2 6 2 Installation Drawing 11 0100...
Page 32: ...OLCT 200 User Manual 32...
Page 36: ...OLCT 200 User Manual 36...
Page 38: ...OLCT 200 User Manual 38 Figure 4 1 Calibration Gas Input...
Page 61: ...OLCT 200 User Manual 61 Figure 6 5...
Page 62: ...OLCT 200 User Manual 62...
Page 79: ...OLCT 200 User Manual 79...