118
Run Down Time settings
Adjustment of delivery at full power.
Only displayed if no combustion chamber sensor is connected.
Exhaust minimum temperature for the control of the boiler performance.
If temperature falls below exhaust minimum temperature, the boiler increases per-
formance regardless of the boiler temperature.
Only displayed if flue gas sensor is connected.
Back to the menu
Pellematic
.
113
3..114
4..6
6 R
Ru
un
n D
Do
ow
wn
n T
Tiim
me
e s
se
ettttiin
ng
gs
s
Adjusting the speed of the burner fan in the full power mode in percent. The speed
reduces continuously in the run on time.
Adjusting the speed of the flue gas fan in the full power mode in percent. The speed
reduces continuously in the run on time.
Minimum run on time of the burner air fan at the moment of switch off in seconds.
Minimum run on time of the flue gas fan at the moment of switch off in seconds.
PE 567 EN 1.1